3.7

Acquire Data

Acquire Data

At this point you are ready to capture data from the ADC. You can do so by clicking on the red circular
Acquire Data button located below the graph. The button turns green and stay green until the capture is
complete. After it is complete, you will see a FFT plot as well as Capture Statistics and FFT Computations.

Capture the ADC Samples, Perform an FFT, and Plot the Results

10

SLAU155 – August 2005

Summary of Contents for TSW1100

Page 1: ...TSW1100 Data Capture Board Quick Start Guide August 2005 SLAU155...

Page 2: ...2 SLAU155 August 2005...

Page 3: ...s 9 3 5 Configure the ADC Sampling Frequency FS Conditions 9 3 6 Configure the TSW1100 Capture 9 3 7 Acquire Data 10 4 Performing a Dual Channel Capture 11 4 1 Information 11 4 2 Setting up Remote Con...

Page 4: ...Contents 4 SLAU155 August 2005...

Page 5: ...in dual channel mode allowing simultaneous capture of a dual channel ADC Data is transferred via a USB interface allowing easy PC control and it requires only one power supply for operation The TSW110...

Page 6: ...www ti com Overview 6 SLAU155 August 2005...

Page 7: ...er that has an output rating of 12 VDC and 500 mA or you can use a lab power supply that can supply a 12 VDVC to J8 while connecting the return to J9 Texas Instruments recommends that you set a curren...

Page 8: ...www ti com Launching the TSW1100 Software Setup the TSW1100 8 SLAU155 August 2005...

Page 9: ...ber of bits and 2 s compliment Find the control labeled Desired Frequency and change it to the sinusoidal frequency you would like to provide to the ADC analog input In its default state and for best...

Page 10: ...icking on the red circular Acquire Data button located below the graph The button turns green and stay green until the capture is complete After it is complete you will see a FFT plot as well as Captu...

Page 11: ...automatically update the ADC characteristic indicators Number of Bits and 2 s Compliment Find the control labeled Desired Frequency and change it to the sinusoidal frequency you would like to provide...

Page 12: ...it for an external trigger which can be applied by either depressing SW1 or providing a trigger stimulus to J5 of the TSW1100 This synchronously captures ADC data on both channel 1 and channel 2 After...

Page 13: ...data format to either decimal or hexadecimal On the Data Capture Selector scroll through the list and select Read From File Once selected click on the red circular Acquire Data button and it prompts y...

Page 14: ...www ti com Performing a Screen Capture Saving and Recalling Data to a File 14 SLAU155 August 2005...

Page 15: ...oftware package it is advised to click on the red circular Exit button located below the graph In doing so all control values will be saved and recorded such that the next time you open the program it...

Page 16: ...s responsibility to take any and all appropriate precautions with regard to electrostatic discharge EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE NEITHER PARTY SHALL BE Liable to the other FOR...

Page 17: ...than xxx C The EVM is designed to operate properly with certain components above xxx C as long as the input and output ranges are maintained These components include but are not limited to linear reg...

Page 18: ...iness practice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product wou...

Reviews: