WR-25 Instruction Manual
Comfort
Hold
29 .9 2
Press
select
a fifth time, and the unit displays in the rainfall window: 0, 1, 2, or
3. 2 is the normal display. Press the
maximum
or
minimum
key to enter the
proper number
(see calibration reference for more information).
Hold
2
D aily
Monthly
IInch
Term
Last
Press
select
a sixth time; the unit will display in the rainfall window a reading
ranging from .01 to .1. Press the
maximum
or
minimum
button to enter the
proper number.
Hold
.01
D aily
Monthly
IInch
Term
Last
Press
select
a seventh time - the unit displays wind direction. Press the
maximum
or
minimum
key to enter the actual wind direction.
Press
select
an eighth time - the unit will return to the normal display mode.
Humidity Sensor Calibration
This function is only used if a new humidity sensor is installed. Press
select
and
humidity
hold
to enter this mode. The first number to appear is the voltage at
0% humidity that the sensor outputs. Press
select
again and a second number
will appear. This larger number is the voltage that the sensor outputs at 75%
humidity. The humidity calibration numbers are found on the
humidity/temperature sensor and on the back of the instrument console. These
calibration numbers are supplied to us by the manufacturer of the sensor and
are normally not changed.