Test Summary
4
SLUUCB3 – June 2020
Copyright © 2020, Texas Instruments Incorporated
Using the UCC27288EVM
4
Test Summary
4.1
Definitions
This procedure details how to configure the UCC27288EVM evaluation board. Within this test procedure,
the following naming conventions are applied. See the UCC27288EVM
Bench Setup Diagram and
Configuration
,
, for details.
DMM:
Digital multimeter
EVM:
Evaluation module
4.2
Equipment
4.2.1
Power Supply
DC power supply with voltage and current above 20 V and 1 A, for example: Agilent E3634A
4.2.2
Function Generator
Two-channel function generator over 10 MHz, for example: Tektronics AFG3252
4.2.3
DMM
DMM with voltage and current above 25 V and 1 A, for example: Fluke 187
4.2.4
Oscilloscope
Four channel oscilloscope with 500 MHz or greater bandwidth, for example: DPO 7054
4.3
Equipment Setup
4.3.1
DC Power Supply Settings
•
DC power supply #1
–
Voltage setting: 12 V
–
Current limit: 0.05 A
4.3.2
Digital Multi-Meter Settings
•
DMM #1
–
DC current measurement, auto-range. Expected current is within 1 mA to 15 mA.
4.3.3
Two-Channel Function Generator Settings
displays the two-channel function generator settings.
Table 2. Two-Channel Function Generator Settings
Mode
Frequency
Width
Delay
High
Low
Output
Impedance
Channel A
Pulse
100 kHz
2.5 µs
0 us
5 V
0 V
High Z
Channel B
2.5 µs
5 µs
The UCC27288 interlock function will result in HO and LO in the low state if HI and LI are high at the
same time.