s
Power
Supply #1
(5V/0.05A)
+
s
Power
Supply #2
(15V/0.1A)
+
s
DMM #2
DC Current
CH1
EVM
Function
Generator
Oscilloscope
D
MM
#
1
D
C
C
u
r
r
e
n
t
+
s
Test Summary
7
SLUUBW3B – October 2018 – Revised June 2020
Copyright © 2018–2020, Texas Instruments Incorporated
UCC2351x Evaluation Module User’s Guide
4.3.6
Bench Setup Diagram
The current bench setup diagram includes the function generator and oscilloscope connections.
Follow the connection procedure below.
can be used as a reference.
•
Make sure the output of the function generator and voltage sources are disabled before connecting.
•
Function generator channel applied on J1-1
←→
J1-2 (see in
)
•
Power supply #1: positive node connected to input of DMM #1 with DMM #1 output connected to P1-1
(or VDD), and negative node applied on P1-2 (or GND).
•
Power supply #2: positive node connected to input of DMM #2 with DMM #2 output connected to P2-1
(or VCC), negative node connected directly to P2-2 (or VSS).
•
Oscilloscope channel-A probes Anode_R
←→
GND, smaller measurement loop is preferred.
•
Oscilloscope channel-B probes VG (or J7-1)
←→
VSS, smaller measurement loop is preferred.
Figure 2. Bench Setup Diagram and Configuration