FUNC_PAD_CONTROL Registers
111
SLVUAH1C – June 2015 – Revised April 2017
Copyright © 2015–2017, Texas Instruments Incorporated
Register Descriptions
3.9.5 OD_OUTPUT_CTRL Register (Address = 1F8h) [reset = 0h]
OD_OUTPUT_CTRL is shown in
and described in
Return to
Open Drain control register
RESET register domain: HWRST
Note: It is user responsibility to take care about the IO direction and type (Open drain / Push-Pull) versus
the pull-up/pull-down selections
Figure 3-94. OD_OUTPUT_CTRL Register
7
6
5
4
3
2
1
0
RESERVED
RESERVED
RESERVED
RESERVED
INT_OD
RESERVED
RESERVED
RESERVED
R-0h
R-0h
R-0h
R-0h
R/W-0h
R-0h
R-0h
R-0h
Table 3-103. OD_OUTPUT_CTRL Register Field Descriptions
Bit
Field
Type
Reset
Description
7
RESERVED
R
0h
6
RESERVED
R
0h
5
RESERVED
R
0h
4
RESERVED
R
0h
3
INT_OD
R/W
0h
0: open drain not enable (Push-Pull enabled) (default)
1: open drain enable (Push-Pull not enable)
2
RESERVED
R
0h
1
RESERVED
R
0h
0
RESERVED
R