background image

Table 7-1. Bill of Materials (continued)

ITEM

QUANTITY DESIGNATOR

VALUE

FOOTPRINT

MANUFACTURER

MANUFACTURER

PART NO.

VENDER PART

NO.

DESCRIPTION

25

1

DNI

C1

22 µF

1210

AVX Corp

12103D226KAT2A

478-5999-6-ND

CAP CER 22000 pF

25 V CERM X7R

0603

26

2

C9A, C11A

22 µF

603

Panasonic-ECG

ECJ-1VB1E223K

PCC1767DKR-ND

CAP 4700 pF 50 V

CERAMIC X7R 0603

27

1

R2

5 kΩ

603

Vishay/Dale

PNM0603E5001BST5

PNM0603-5.0KBDK

R-ND

RES 5.0 kΩ

15W 0.1% 0603

SMD

28

2

R5, R16

49.9 kΩ

603

Panasonic-ECG

ERJ-3EKF4992V

P49.9KHDKR-ND

RES 49.9 kΩ

1/10W 1% 0603

SMD

8 Revision History

NOTE: Page numbers for previous revisions may differ from page numbers in the current version.

Changes from Revision A (November 2015) to Revision B (May 2021)

Page

• Updated user's guide title...................................................................................................................................

2

• Updated the numbering format for tables, figures, and cross-references throughout the document. ................

2

Changes from Revision * (June 2011) to Revision A (November 2015)

Page

• Updated schematic image..................................................................................................................................

4

Revision History

www.ti.com

12

TPS65253 Buck Converter Evaluation Module User's Guide

SLVU469B – JUNE 2011 – REVISED MAY 2021

Submit Document Feedback

Copyright © 2021 Texas Instruments Incorporated

Summary of Contents for TPS65253

Page 1: ...and Jumper Placement 8 5 2 Jumpers 9 5 3 Test Points and Placement 9 6 Power Up Procedure 10 7 Bill of Materials 11 8 Revision History 12 Trademarks All trademarks are the property of their respectiv...

Page 2: ...S65253 PMIC as well as the support documentation including schematic and bill of materials Introduction www ti com 2 TPS65253 Buck Converter Evaluation Module User s Guide SLVU469B JUNE 2011 REVISED M...

Page 3: ...nd Output Current Summary EVM TEST CONDITIONS OUTPUT CURRENT RANGE TPS65253EVM VIN 4 5 V to 16 V fsw 500 kHz Buck1 1 2 V 3 5 A Buck2 3 3 V 2 5 A 25 C ambient This evaluation module is designed to prov...

Page 4: ...17 COMP2 18 FB2 19 LOW_P SDA 20 V7V 21 V3p3 22 V3p3 23 PGOOD 24 PB 25 MR SCL 26 LH 27 INT 28 PP 29 U1 TPS65253 3 3uF C22 TP24 V3p3 100K R24 0 R25 TP25 TP26 TP28 383K R1 V7V V3p3 100K R28 FB1 100pF DNI...

Page 5: ...Part Placement Figure 4 2 Top Layer www ti com Placement SLVU469B JUNE 2011 REVISED MAY 2021 Submit Document Feedback TPS65253 Buck Converter Evaluation Module User s Guide 5 Copyright 2021 Texas Ins...

Page 6: ...Layer 1 Figure 4 4 Mid Layer 2 Placement www ti com 6 TPS65253 Buck Converter Evaluation Module User s Guide SLVU469B JUNE 2011 REVISED MAY 2021 Submit Document Feedback Copyright 2021 Texas Instrumen...

Page 7: ...re 4 5 Bottom Layer www ti com Placement SLVU469B JUNE 2011 REVISED MAY 2021 Submit Document Feedback TPS65253 Buck Converter Evaluation Module User s Guide 7 Copyright 2021 Texas Instruments Incorpor...

Page 8: ...Headers Description and Jumper Placement Test points Black GND White Each output feed back power good and VIN All marking on PCB Bench Test Setup Conditions www ti com 8 TPS65253 Buck Converter Evalua...

Page 9: ...asy location Close to any of these test points there are black ground test points to allow for DVM measurement or to use a metal exposed scope probe to reduce common mode noise measurements All test p...

Page 10: ...rs are powered up by the output voltages The whole start up process will take less than 100 ms PGOOD will be asserted high 32 ms after all converter outputs have reached 90 of nominal voltages 4 Apply...

Page 11: ...th Electronics 7440650022 732 1055 2 ND INDUCTOR POWER 2 2 H 6 2 A SMD 12 1 R1 383 k 603 Panasonic ECG ERJ 3EKF3833V P383KHDKR ND RES 383 k 1 10 W 1 0603 SMD 13 1 R18 10 k 603 Panasonic ECG ERJ 3EKF10...

Page 12: ...nasonic ECG ERJ 3EKF4992V P49 9KHDKR ND RES 49 9 k 1 10W 1 0603 SMD 8 Revision History NOTE Page numbers for previous revisions may differ from page numbers in the current version Changes from Revisio...

Page 13: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 14: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 15: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 16: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 17: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 18: ...are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and...

Reviews: