Introduction
4
SLVUBO0A – March 2020 – Revised May 2020
Copyright © 2020, Texas Instruments Incorporated
Using the TPS54JA20EVM-023 12-A, Buck Converter Evaluation Module
1.3.2
Frequency and Operation Mode Setting
To change the frequency and operation mode of the part, the MODE pin is used. J6 and the surrounding
circuitry allows for an easy change to the frequency and operation mode setting. All 6 options offered by
J6 are shown in
Table 3. TPS54JA20EVM Mode Pin Selection
Switching Frequency (F
SW
)
Operation Mode Under
Light Load
Mode Pin Connections
Connection
Jumper Setting
600 kHz
Skip Mode
Short to VCC
Short Pins 1 and 2
800 kHz
Skip Mode
243k
Ω
+/- 10% to AGND
Short Pins 3 and 4
1000 kHz
Skip Mode
121k
Ω
+/- 10% to AGND
Short Pins 5 and 6
1000 kHz
Forced CCM
60.4k
Ω
+/- 10% to AGND
Short Pins 7 and 8
800 kHz
Forced CCM
30.1k
Ω
+/- 10% to AGND
Short Pins 9 and 10
600 kHz
Forced CCM
Short to AGND
Short Pins 11 and 12
1.3.3
Enable Pin Selection
The converter can be enabled and disabled by J5.
Default setting: EN pin connected to VIN.
Table 4. Enable Pin Selection
Set On Connection
Enable Selection
Pins 2-3 Shorted
EN pin connected to VIN pins through resistor divider
J3 Open
EN pin is left floating
Pins 1-2 Shorted
EN pin connected to PGND
1.3.4
Remote Sensing
The EVM is not set-up for remote sensing by default. To set up remote sensing follow these steps:
1. Replace R8 and R11 with 100
Ω
resistors
2. Connect your sense points to the Vsns+ and Vsns- test points
1.3.5
Adjustable UVLO
The undervoltage lockout (UVLO) can be adjusted externally using R2 and R9. See the TPS54JA20 Data
Sheet to get detailed instructions for setting the external UVLO.