4.2 Equipment Setup
Shown in
is the basic test set up recommended to evaluate the TPS54383EVM. Please note that
although the return for J1, J2 and JP3 are the same system ground, the connections should remain separate as
shown in
4.2.1 Procedure
1. Working at an ESD workstation, make sure that any wrist straps, bootstraps or mats are connected
referencing the user to earth ground before power is applied to the EVM. Electrostatic smock and safety
glasses should also be worn.
2. Prior to connecting the dc input source, VIN, it is advisable to limit the source current from VIN to 5.0 A
maximum. Make sure VIN is initially set to 0 V and connected as shown in
.
3. Connect the ammeter A1 (0-5 A range) between VIN and J1 as shown in
.
4. Connect voltmeter V1 to TP1 and TP2 as shown in
5. Connect LOAD1 to J2 as shown in
. Set LOAD1 to constant current mode to sink 0 A
DC
before
VIN is applied.
6. Connect voltmeter, V2 across TP3 and TP4 as shown in
7. Connect LOAD2 to J3 as shown in
. Set LOAD2 to constant current mode to sink 0 A
DC
before
VIN is applied.
8. Connect voltmeter, V3 across TP18 and TP19 as shown in
9. Place fan as shown in
and turn on, making sure air is flowing across the EVM.
4.2.2 Diagram
LOAD1
5.0V @
2A
-
+
FAN
V2
-
+
See Tip and Barrel
Measurement for Vout
ripple
V1
+
-
A1
-
+
V
VIN
Oscilloscope
1M
W
, AC
20mV / div
20MHz
LOAD2
3.3V @
2A
+
-
V3
-
+
Figure 4-1. TPS54383EVM Recommended Test Set-Up
Test Set Up
SLUU285D – JULY 2007 – REVISED OCTOBER 2021
TPS54383 Step-Down Converter Evaluation Module User's Guide
9