3.12 Overvoltage Protection
show the overvoltage protection behavior of U2. This is tested by applying a step to
the FB pin with a function generator through the VO_ADJ test point. The VO_ADJ test point is initially equal to
the reference voltage of 0.5 V and is stepped up to 3.3 V. The TPS543820 attempts to restart immediately after
the OVP fault is cleared. It does not wait for the hiccup time period.
Time (10 µs/div)
VOUT (500 mV/div)
SW (10 V/div)
VOADJ (2 V/div)
IL (5 A/div)
Figure 3-38. U2 Overvoltage Protection
Time (200 µs/div)
VOUT (500 mV/div)
SW (10 V/div)
VOADJ (2 V/div)
IL (5 A/div)
Figure 3-39. U2 OVP and Recover
Test Setup and Results
24
TPS543820EVM SWIFT™ Step-Down Converter Evaluation Module User's
Guide
SLUUCE9A – DECEMBER 2020 – REVISED APRIL 2021
Copyright © 2021 Texas Instruments Incorporated