3.11 Hiccup Current Limit
show the TPS543620 hiccup current limit feature. These waveforms are
and
show the response to an overload with the High and Low
current limit settings.
and
show the response to a hard short on the output with the High
and Low current limit settings.
shows the TPS543620 entering hiccup with an overload on the output and the High current limit
setting with a longer timescale. The TPS543620 tries to restart after the Hiccup wait time period but the overload
was still present on the output. In the next restart attempt, the overload has been removed so the TPS543620
starts up normally.
Time (20 µs/div)
SW (5 V/div)
VOUT (500 mV/div)
IL (5 A/div)
Figure 3-33. U2 Output Overcurrent Protection –
Overload with High Limit
Time (20 µs/div)
VOUT (500 mV/div)
SW (5 V/div)
IL (2 A/div)
Figure 3-34. U2 Output Overcurrent Protection –
Overload with Low Limit
Time (10 µs/div)
VOUT (500 mV/div)
SW (5 V/div)
IL (2 A/div)
Figure 3-35. U2 Output Overcurrent Protection –
Short with Low Limit
Time (2 ms/div)
VOUT (500 mV/div)
SW (5 V/div)
IL (5 A/div)
Figure 3-36. U2 OCP Hiccup and Recover – High
Limit
Test Setup and Results
SLVUBQ1A – AUGUST 2020 – REVISED MAY 2021
TPS543620 SWIFT™ Step-Down Converter Evaluation Module User's Guide
23