6 Configurations
All Jumper selections should be made prior to applying power to the EVM. User can configure this EVM per
following configurations.
6.1 Mode and Soft-Start Time Selection
The operation mode and soft-start time can be set by J4.
6.1.1 Default Setting: Skip Mode, 6-ms SS
Table 6-1. MODE Selection
MODE RESISTANCES
OPERATION MODE
SOFT-START TIME
10.0 kΩ
FCCM
6 ms
20.0 kΩ
FCCM
3 ms
39.0 kΩ
FCCM
1 ms
82.0 kΩ
Skip
6 ms
160 kΩ
Skip
3 ms
Open
Skip
1 ms
6.2 Overcurrent Protection (OCP) Selection
The OCP threshold can be set by J6.
6.2.1 Default Setting: 9-A OCP
Table 6-2. OCP Selection
OCP SETTING CAPACITANCE
OVERCURRENT LIMIT
10 nF
9 A
2.2 nF
4.5 A
Open
6 A
6.3 Enable Selection
The converter can be enabled and disabled by J1.
6.3.1 Default Setting: Short to Disable the Converter
6.4 Switching Frequency Selection or External Clock Input for Synchronization
The switching frequency can be set by J3. If the external clock is used for synchronization, the external clock
should be connected to TP5 (SYNC) and TP7 (GND).
6.4.1 Default setting: 600 kHz
Table 6-3. Switching Frequency Selection
SWITCHING FREQUENCY SETTING RESISTANCES
SWITCHING FREQUENCY
80.6 kΩ
600 kHz
45.3 kΩ
1.00 MHz
Configurations
SLUU819A – DECEMBER 2011 – REVISED DECEMBER 2021
TPS53313 Step-Down Converter Evaluation Module User's Guide
7
Copyright © 2021 Texas Instruments Incorporated