7 Performance Data and Typical Characteristic Curves
through
present typical performance curves for the TPS53126EVM-600. Because actual
performance data can be affected by measurement techniques and environmental variables, these curves are
presented for reference and may differ from actual field measurements.
7.1 Efficiency
95
90
85
80
75
70
65
60
h
- Efficiency - %
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
I
- Load Current - A
LOAD
V
= 8 V
IN
V
= 12 V
IN
V
= 22 V
IN
(a) F
= 350 kHz
SW
95
90
85
80
75
70
65
60
h
- Efficiency - %
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
I
- Load Current - A
LOAD
V
= 8 V
IN
V
= 12 V
IN
V
= 22 V
IN
(b) F
= 700 kHz
SW
Figure 7-1. Efficiency vs Load (V
IN
= 8 V–22 V, V
OUT1
= 1.05 V, I
OUT1
= 0 A–4 A)
95
90
85
80
75
70
65
60
h
- Efficiency - %
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
I
- Load Current - A
LOAD
(a) F
= 350 kHz
SW
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
I
- Load Current - A
LOAD
95
90
85
80
75
70
65
60
h
- Efficiency - %
V
= 8 V
IN
V
= 12 V
IN
V
= 22 V
IN
V
= 8 V
IN
V
= 12 V
IN
V
= 22 V
IN
(a) F
= 700 kHz
SW
Figure 7-2. Efficiency vs Load (V
IN
= 8 V–22 V, V
OUT2
= 1.8 V, I
OUT2
= 0 A–4 A)
Performance Data and Typical Characteristic Curves
SLVU435A – FEBRUARY 2011 – REVISED JANUARY 2022
TPS53126 Buck Controller Evaluation Module User's Guide
11
Copyright © 2022 Texas Instruments Incorporated