General Configurations
3
SLVUAY7B – November 2016 – Revised January 2018
Copyright © 2016–2018, Texas Instruments Incorporated
TPS22810 Load Switch Evaluation Module
Table 3. Test Points Description (continued)
Channel
Test Points
Label
Description
CH2
TP9
VIN2
CH2 power supply input
TP10
VIN2_SENSE
CH2 input voltage sense
TP11
VOUT2_SENSE
CH2 output voltage sense
TP12
VOUT2
CH2 output voltage
TP13
CT
CH2 slew rate control voltage
TP14
EN2
CH2 enable input
TP15, TP16
GND2
GND
Table 4. Jumper and LED Descriptions
Jumper
Label
Description
J1
UVLO
CH1 UVLO selection
spac
1-2 position disables the device
spac
2-3 position sets default UVLO and enables the device
spac
Open position sets UVLO according to R4 and R5 ratio
J2
QOD
CH1 Quick Output Discharge (QOD) resistance selection
spac
1-2 position sets 511-
Ω
external resistance in series with the QOD pin
spac
3-4 position sets 249-
Ω
external resistance in series with the QOD pin
spac
5-6 position sets default internal value
spac
Open position disables QOD function
J3
J3
CH1 10-µF capacitor connects to VOUT1, if installed
J4
J4
CH1 output power indicator LED pulled to VOUT1, if installed
J5
UVLO
CH2 UVLO selection
spac
1-2 position disables the device
spac
2-3 position sets default UVLO and enables the device
spac
Open position sets UVLO according to R9 and R10 ratio
J6
QOD
CH2 Quick Output Discharge (QOD) resistance selection
spac
1-2 position sets 511-
Ω
external resistance in series with the QOD pin
spac
3-4 position sets 249-
Ω
external resistance in series with the QOD pin
spac
5-6 position sets default internal value
spac
Open position disables QOD function
J7
J7
CH2 10-µF capacitor connects to VOUT2, if installed
J8
J8
CH2 output power indicator LED pulled to VOUT2, if installed
D1, D2 (GREEN-
LED)
Output power indicator
CH1, CH2 output power indicators, respectively. LED turns on whenever the
output voltage is available.
3.2
Test Equipment
This section lists the following equipment required for test setup.
3.2.1
Power Supplies
One adjustable power supply: 0- to 20-V output, 0- to 3-A output current limit.
3.2.2
Meters
One DMM minimum needed and may require more if simultaneous measurements are required.
3.2.3
Oscilloscope
A DPO2024, or equivalent. Three 10× voltage probes and one DC current probe.