background image

Quick Start List for Platform

2-3

Quick Start

2.2

Quick Start List for Platform

Follow these steps when using the TPA721 MSOP EVM with the TI plug-n-play
audio amplifier evaluation platform (see the platform user’s guide, SLOU011,
for additional details). Numbered callouts for selected steps are shown in
Figure 2–1 and details appear in Chapter 3.

-

Platform preparations

1) Ensure that all external power sources are set to OFF and that the platform

power switch S1 is set to OFF.

2) Install a TPA721 MSOP module in platform sockets U3 and U4 for stereo

operation (or a module in either U3 or U4 for single channel operation),
taking care to align the module pins correctly.

3) Use switch S2 to select or bypass the signal conditioning EVM (U1).

4) Set control signal Polarity jumper JP8 to Hi.

5) Set jumper JP6 to select the Mute control input (causes the TPA721 to

shut down if a plug is inserted into platform headphone jack J10).

Table 2–2. Platform Jumper and Switch Settings for the TPA721 MSOP EVM

EVM

JP6

JP7

JP8

S2

S3

TPA721

Mute

X

Hi

Note 2

X

Notes:

1) X = Don’t care
2) Set S2 to ON when signal conditioning board is installed in U1; set S2

to OFF when no signal conditioning board is installed.

-

Power supply

6) Select and connect the power supply:

a) Connect an external regulated power supply set to a voltage between

2.5 V and 5.5 V to platform V

DD

 power input connector J6, taking care

to observe marked polarity,
        or

b) Install a voltage regulator EVM (SLVP097 or equiv.) in platform socket

U6. Install a 9-V battery in B1 or connect a 7 V – 12 V power source
to a platform V

CC

 power input J1 or J2 and jumper the appropriate

power input (see platform user’s guide).

-

Inputs and outputs

7) Ensure that signal source level is set to minimum.

8) Connect the audio source to left and right RCA phono jacks J3 and J5 or

stereo miniature phone jack J4.

9) Connect 8-

 – 32-

 speakers to left and right RCA jacks J7 and J9 or to

stripped wire connectors J8.

-

Power Up

10) Verify correct voltage and input polarity and set the external power supply

to ON.  If V

CC

 and an on-board regulator EVM are used to provide V

DD

,

set platform power switch S1 to ON.

Platform LED2 should light indicating the presence of V

DD

, and the evaluation

modules installed on the platform should begin operation.

11) Adjust the signal source level as needed.

Summary of Contents for TPA721

Page 1: ...2001 Mixed Signal Products TPA721 MSOP Audio Power Amplifier Evaluation Module User s Guide SLOU033A...

Page 2: ...esign TI does not warrant or represent that any license either express or implied is granted under any patent right copyright mask work right or other intellectual property right of TI covering or rel...

Page 3: ...This equipment is intended for use in a laboratory test environment only It generates uses and can radiate radio frequency energy and has not been tested for compliance with the limits of computing de...

Page 4: ...iv...

Page 5: ...Amplifier Evaluation Module 3 3 3 2 1 TPA721 Audio Amplifier IC 3 4 3 2 2 BTL Operation 3 4 3 2 3 Module Gain 3 4 3 2 4 Shutdown 3 5 3 2 5 Internal Depop Circuitry 3 5 3 3 Using The TPA721 MSOP EVM Wi...

Page 6: ...3 3 3 3 TPA721 MSOP EVM Schematic Diagram 3 3 3 4 TPA721 Audio Amplifier IC 3 4 3 5 Platform Signal Routing and Outputs 3 7 3 6 Mute Mode and Polarity Control 3 8 3 7 Typical Headphone Plug 3 10 3 8 T...

Page 7: ...21 MSOP audio amplifier evaluation module SLOP215 It includes a list of EVM features a brief description of the module illustrated with a pictorial diagram and a list of EVM specifications Topic Page...

Page 8: ...signed to simply plug into the platform automatically making all signal control and power connections J Platform provides flexible power options J Jumpers on the platform select power and module contr...

Page 9: ...EVM to be plugged into the TI plug n play audio amplifier evaluation platform or to be wired directly into existing circuits and equipment when used stand alone The platform with room for a pair of TP...

Page 10: ...1 4 Introduction...

Page 11: ...directly into existing circuits or equipment The platform switch and jumper settings shown in Table 2 1 are typical for the TPA721 MSOP EVM They will cause the TPA721 amplifier IC on the EVM to shut...

Page 12: ...or both may result Figure 2 1 Quick Start Platform Map Signal Conditioning CAUTION Do not insert or remove EVM boards with power applied ICC JP4 F1 VR1 R1 JP3 JP2 JP1 AC DC J2 VCC J1 D1 D2 D3 D4 J2 J...

Page 13: ...X Don t care 2 Set S2 to ON when signal conditioning board is installed in U1 set S2 to OFF when no signal conditioning board is installed Power supply 6 Select and connect the power supply a Connect...

Page 14: ...M C6 C5 S1 R1 R2 C2 C1 R3 R4 C3 Due to the very small size of the MSOP IC package the standard part number TPA721 is replaced with the code TIABC Power supply 1 Ensure that all external power sources...

Page 15: ...n and a parts list for the TPA721 MSOP evaluation module Topic Page 3 1 Precautions 3 2 3 2 The TPA721 MSOP Audio Power Amplifier Evaluation Module 3 3 3 3 Using The TPA721 MSOP EVM With The Plug N Pl...

Page 16: ...or both may result Figure 3 1 The TI Plug N Play Audio Amplifier Evaluation Platform Signal Conditioning CAUTION Do not insert or remove EVM boards with power applied ICC JP4 F1 VR1 R1 JP3 JP2 JP1 AC...

Page 17: ...tput power and control connections to the module The module connection pins are on 0 1 inch centers to allow easy use with standard perf board and plug board based prototyping systems Or the EVM can b...

Page 18: ...ied load BTL configuration for increased power BTL operation provides many benefits including quadruple the output power of single ended operation and no need for bulky output coupling capacitors For...

Page 19: ...lished by applying a control signal to the module shutdown pin S1 or by pressing the shutdown switch on the module When the control signal goes low or is removed or the switch is released amplifier op...

Page 20: ...ly with the proper orientation Evaluation modules are easily removed from the platform by simply prying them up and lifting them out of their sockets Care must be taken however to prevent bending the...

Page 21: ...with a shutdown mute control input pin When this input is tied to VDD the TPA721 amplifier IC on the module shuts down and assumes a low power mode When the EVM control input is tied to GND or allowed...

Page 22: ...er JP6 to MUTE J To not affect the TPA721 amplifier when a plug is inserted into the headphone jack jumper JP6 to Mode or leave JP6 unjumpered 3 3 3 3 Mute Mode Polarity Select JP8 A second 3 pin jump...

Page 23: ...n be used to supply VDD voltage to the platform and the TPA721 MSOP evaluation modules installed on it The platform is equipped with overvoltage and reverse polarity supply voltage input protection in...

Page 24: ...nal input jacks J3 J4 and J5 are of the closed circuit type grounding the signal input lines when no plugs are inserted 3 3 5 2 Outputs Amplified audio output signals leave the platform through left a...

Page 25: ...t to overcome the pulldown resistors on the modules 20 k 20 k for two EVMs 3 4 1 TPA721 MSOP EVM Connected for BTL Output Figure 3 8 TPA721 MSOP EVM Connected for Stereo BTL Output Audio Input Left Ex...

Page 26: ...603 0 R1 R4 Resistor 20 k 1 16 W 5 0603 2 Panasonic ERJ 3GSYJ203 Digi Key P20KGCT ND R5 Resistor 39 k 1 16 W 5 0603 1 Panasonic ERJ 3GSYJ393 Digi Key P39KGCT ND R2 Resistor 0 1 16 W 0603 1 Panasonic E...

Page 27: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments TPA721MSOPEVM...

Reviews: