STC Control Registers
457
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Self-Test Controller (STC) Module
10.8.13 Segment Interval Preload Register (STCSEGPLR)
This register is described in
. This register is used to specify the segment for which the first
interval will be run. The address of the first interval of the selected segment is loaded to the STC ROM
address counter before the test is started.
Figure 10-26. Segment Interval Preload Register (STCSEGPLR) [offset = 48h]
31
16
Reserved
R-0
15
2
1
0
Reserved
SEGID_PLOAD
R-0
RWP-0
LEGEND: R/W = Read/Write; R = Read only; WP = Write in privilege mode only; -
n
= value after nPORST (power on reset) or System reset
Table 10-21. Segment Interval Preload Register (STCSEGPLR) Field Descriptions
Bit
Field
Value
Description
31-2
Reserved
0
Reads return 0. Writes have no effect.
1-0
SEGID_PLOAD
Specifies the segment for the first interval to be run.
0
Preload the address of the 1st interval for Segment 0.
1
Preload the address of the 1st interval for Segment 1.
All other values