FlexRay Module Registers
1378
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.4.3 Slot Counter Value (SCV)
This register is reset when the Communication Controller leaves CONFIG state or enters STARTUP state.
and
illustrate this register.
Figure 26-148. Slot Counter Vector Register (SCV) [offset_CC = 110h]
31
27
26
16
Reserved
SCCB
R-0
R-0
15
11
10
0
Reserved
SCCA
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-127. Slot Counter Vector Register (SCV) Field Descriptions
Bit
Field
Value
Description
31-27
Reserved
0
Reads return 0. Writes have no effect.
26-16
SCCB
1h-7FFh
Slot counter channel B. Current slot counter value channel B. The value is incremented by the
communication controller and reset at the start of a communication cycle.
15-11
Reserved
0
Reads return 0. Writes have no effect.
10-0
SCCA
1h-7FFh
Slot counter channel A. Current slot counter value channel A. The value is incremented by the
communication controller and reset at the start of a communication cycle.
26.3.2.4.4 Macrotick and Cycle Counter Value (MTCCV)
and
illustrate this register.
Figure 26-149. Macrotick and Cycle Counter Register (MTCCV) [offset_CC = 114h]
31
22
21
16
Reserved
CCV
R-0
R-0
15
14
13
0
Reserved
MTV
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-128. Macrotick and Cycle Counter Register (MTCCV) Field Descriptions
Bit
Field
Value
Description
31-22
Reserved
0
Reads return 0. Writes have no effect.
21-16
CCV
0-3Fh
Cycle counter value. Current cycle counter value. The value is incremented by the communication
controller at the start of a communication cycle.
15-14
Reserved
0
Reads return 0. Writes have no effect.
13-0
MTV
0-3E80h
Macrotick value. Current macrotick value. The value is incremented by the communication
controller and reset at the start of a communication cycle.