background image

C2000™ Systems Applications Collateral 

 

 

 

v2.0

 

6)  The GUI should auto-detect and connect to your HVDMC Kit. If auto-connect fails  you  will need to set 

up  the  connection  manually.  The  Connection Wizard  is  accessed  through  the  Connection  menu. Click 
on “Connect to engine” to view a list of available targets. Now setup the Connection Wizard Dialog to 
match Fig 5. Select Piccolo 28035 from the Target list and Serial for connection method. You will need 
to  determine  the  correct  COM  port  number  for  your  system.  This  can  be  found  by  going  to  Control 
Panel->System->Hardware  tab->Device  Manager->Ports(COM  &  LPT).  And  look  for  the  one  which  is 
described as USB Serial Port or similar. Hit Connect once done. Now select the appropriate COM port. 
This can be found out by going to  
 

Control Panel->System->Hardware tab->Device Manager->Ports (COM & LPT).     
 

 

And look for the one which is described as USB Serial Port or similar. Hit OK once done. 

 
 
 

 

 
 

Fig5: GUI Setup Connections 

 
 
 
 
 
 

Summary of Contents for TMDSHVMTRPFCKIT

Page 1: ...the controlCARD 15V DC Power Supply AC power Cord Banana Plug Cord USB Cable CCSv5 CD USB Stick with Quick Start GUI and Guide WARNING This EVM should be used only by qualified engineers and technicians who are familiar with the risks associated with handling electrical and mechanical components systems and subsystems The EVM operates at voltages and currents that can result in electrical shock fi...

Page 2: ...he system variables on an oscilloscope Hardware Developer s Package available which includes schematics bill of materials Open source software available through controlSUITE for each type of the motor and control type For detailed feature list and power ratings and safety related information refer to the kit s HW Reference guide The software available with the kit is pre optimized for the motors t...

Page 3: ...tage can then be used for input of the PFC stage or used to generate the DC bus for the inverter directly Aux Power Supply Module M2 This module can take up to 400V input and generate 5V and 15V DC power Rectified AC input can directly be connected to this module or output from the PFC stage cane be used with appropriate jumper settings Iso USB to JTAG Macro M3 Provided on board isolated JTAG conn...

Page 4: ...CCS The interactive interface using sliders buttons textboxes and graphs enables easy demo of sensorless control of ACI PMSM and BLDC Motors Hardware Setup Note Do not apply AC power to board before you have verified these settings The kit ships with the control card inserted and the jumper and switch settings pre done for connecting with the GUI However the user must ensure that these settings ar...

Page 5: ...dows should now be able to find the driver and would install it If Windows still does not find the driver you may have to repeat the process and point to the location pointed out previously You may have to reboot the computer for the drivers to come into effect Once installed you can check if the installation was completed properly by browsing to ControlPanel System Hardware Device Manager and loo...

Page 6: ...formance levels achievable using the TI DMC library Please refer to the individual system software and corresponding literature for details These can be downloaded through controlSUITE The flash images can be re flashed using CCSv5 if need be The image can be found in the drive shipped with the kit or at the following location controlSUITE developement_kits HVMotorCtrl PfcKit_v2 0 GUI HVMTRPFCKIT ...

Page 7: ...e 4 Now connect the other end of the AC power cord to mains wall power outlet Use an assembly such that a switch is in place between the mains supply and the board For example this can achieved using an extension cable 5 Once the mains is connected the board would power up and you would see that the Main LD1 on the board is green indicating power and LD3 Red on the board is blinking slowly indicat...

Page 8: ...olo 28035 from the Target list and Serial for connection method You will need to determine the correct COM port number for your system This can be found by going to Control Panel System Hardware tab Device Manager Ports COM LPT And look for the one which is described as USB Serial Port or similar Hit Connect once done Now select the appropriate COM port This can be found out by going to Control Pa...

Page 9: ...MSM motor Park D value would remain close to zero 9 Once the Motor Enable button is clicked the motor accelerates to the speed reference value and the speed loop is closed The time taken for motor to ramp up to a particular speed would depend on motor type Hence provide for enough time for the motor to ramp up to the speed set The motor can be stopped and started number of times Note that each tim...

Page 10: ...ining various files related to the hardware on the kit board schematics bill of materials Gerber files PCB layout etc controlSUITE development_kits HVMotorCtrl PFCKit_v2 0 HVMotorCtrl PfcKit_HWdevPkg HighVoltageMotorCtrl PFC How to Run Guide presents more information on the HW setup required and software installation that need to be done for using projects associated with the kit controlSUITE deve...

Reviews: