www.ti.com
TLV320AIC34EVM Software
Headset detection features are enabled using the
Enable
button in the
Headset Detection
groupbox.
When enabled, the indicators in the
HS/Button Detect
groupbox will light when either a button press or
headset is detected. When a headset is detected, the type of headset is displayed in the
Detection Type
indicator. Debounce times for detection are set using the
Jack Detect Debounce
and
Button Press
Debounce
controls, which offer debounce times in varying numbers of milliseconds. See the
TLV320AIC34
data sheet for a discussion of headset detection.
Output short-circuit protection can be enabled in the
Short Circuit Protection
groupbox. Short Circuit
Protection can use a current-limit mode, where the drivers will limit current output if a short-circuit
condition is detected, or in a mode where the drivers will power down when such a condition exists.
The
I
2
C Bus Error Detection
button allows the user to enable circuitry which will set a register bit
(Register 107, D0) if an I
2
C bus error is detected.
TLV320AIC34EVM-K
30
SLAU232 – December 2007
Submit Documentation Feedback
Summary of Contents for TLV320AIC34EVM-K
Page 46: ...www ti com...