shows the sensor inputs at a range of 3 mm above the magnet.
Angle (deg)
Mag
netic Flux
Den
sity (m
T)
0
45
90
135
180
225
270
315
360
-100
-80
-60
-40
-20
0
20
40
60
80
100
Bx
By
Figure 2-14. On-Axis Magnetic Field Inputs
2.3.5 Expected Performance
Based on the simulation results in
,
, and
, it is now possible to estimate any
angle error resulting from amplitude mismatch or non-sinusoidal inputs.
• TMAG5170 Error
Figure 2-15. Expected TMAG5170 In-Plane Angle Error
System Overview
12
Absolute Angle Encoder Reference Design With Hall-Effect Sensors for
Precise Motor Position Control
Copyright © 2022 Texas Instruments Incorporated