Test Results
72
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
Class B was claimed as there was no significant network utilization reduction, from the average of around
20% during the UDP packet throughput test as shown in
. During the packet error test, the network
utilization dropped from 5% to 1% due to a laptop issue when a packet lost was detected.
図
図
65. IEC61000-4-4 ±4-kV EFT: Network Utilization With UDP Throughput Test on Gigabit Ethernet Port 1
図
図
66. IEC61000-4-4 ±4-kV EFT: Network Utilization With UDP Packet Error Test on Gigabit Ethernet Port 1
During the test, the UDP packet error test program printed the packet number for every packet lost as well
as the total submitted packets. The total number of submitted packets during the EFT event was 60,680
packets (1526 bytes each). The number of lost packets was 100. However, there was not a single event