Software Overview
14
SLOU464A – March 2017 – Revised October 2017
Copyright © 2017, Texas Instruments Incorporated
TAS6422-Q1 Evaluation Module
Figure 14. Other Control Section
3.5.2.4
Faults and Warnings Section
The top right buttons on this box serve as controlling and monitoring faults.
Clip enable route the clip detection bit to the warning pin. This is displayed as yellow LED on the EVM.
Thermal enable route the over-temperature warning bit to the warning pin. This is display as the same
yellow LED on the EVM.
Clear button clears all the faults and warnings.
Read button manually read the faults and warnings.
Figure 15. Faults and Warnings Section