User’s Guide
SWRU321A
– May 2013
Page 21/32
6.9 LEDs
6.9.1 General Purpose LEDs
The four LEDs D601, D602, D603, D604 can be controlled from the mounted EM and are suitable
for demo use and debugging. The LEDs are active high. Table 11 shows an overview of I/O
signals related to the LEDs.
Signal name
Description
Probe header
EM pin
LV_LED_1
LED 1 (red)
RF2.11 (P407.10)
RF2.11
LV_LED_2
LED 2 (yellow)
RF2.13 (P411.2)
RF2.13
LV_LED_3
LED 3 (green)
RF1.2 (P406.1)
RF1.2
LV_LED_4
LED 4 (red-orange)
RF1.4 (P406.2)
RF1.4
Table 11
– General purpose LED signal connections
6.9.2 XDS100v3 Emulator LEDs
The XDS100v3 emulator has two LEDs to indicate its status, D2 and D4. The LEDs are located
on the top side of the SmartRF06EB. LED D2 is lit whenever the XDS100v3 Emulator is powered,
while LED D4 (ADVANCED MODE) is lit when the XDS100v3 is in an active cJTAG debug state.
6.10 EM Connectors
The EM connectors, shown in Figure 15, are used for connecting an EM board to the
SmartRF06EB. The connectors RF1 and RF2 are the main interface and are designed to inhibit
incorrect mounting of the EM board. The pin-out of the EM connectors is given in Table 12 and
Table 13.
Figure 15
– SmartRF06EB EM connectors RF1 and RF2