www.ti.com
Solar Energy Harvester Module (SEH-01) Operating Characteristics
3.3
Solar Energy Harvester Module (SEH-01) Operating Characteristics
shows the operating characteristics of the Solar Energy Harvester Module.
Table 3-1. SEH-01 Operating Characteristics
PARAMETER
CONDITION
MIN
TYP
MAX
UNIT
Minimum operating lux
200
lux
Input luminous intensity
(1)
Full charge rate
700
lux
Boost converter off
800
nA
Parasitic load current
Boost converter on
20
m
A
1000 lux (FL), battery not charging
350
m
W
Average output power
(measured at V
OUT2
pin)
200 lux (FL), Battery not charging
80
m
W
Output voltage, V
OUT2
2-
m
A load, Battery charged
3.5
3.55
3.6
V
V
BAT
charging voltage
4.06
V
Battery cutoff voltage
3
3.3
3.6
V
Pulse discharge current
20 ms
30
mA
Self discharge rate (non-recoverable average)
25°C, Per year
2.5
%
Operating temperature
0
25
70
°C
10% depth-of-discharge
5000
25°C
Recharge cycles
50% depth-of-discharge
1000
(to 80% of rated capacity,
10% depth-of-discharge
2500
4.1-V charge voltage)
40°C
50% depth-of-discharge
500
Recharge time (to 80% of rated capacity)
4.1-V constant voltage
500
min
Capacity
8-
m
A discharge; 25°C
100
m
Ah
(1)
Fluorescent (FL) light conditions specifications subject to change without notice.
3.4
Solar Energy Harvester Module (SEH-01) Circuit Schematic
shows a schematic of the Solar Energy Harvester module.
Figure 3-3. Solar Energy Harvester Module Schematic
15
SLAU273C – January 2009 – Revised May 2010
Solar Energy Harvester Module (SEH-01)
Copyright © 2009–2010, Texas Instruments Incorporated