2.1.9  RI-STU-TRDC-01 (CN1) Pin Assignments

1

2

3

4

5

6

7      8

16

15

14

13

12

11

10    9

Figure 3:  16-pin Right-Angle Header
Connector (CN1)

1

Component Side

PCB

PCB

Summary of Contents for S6350

Page 1: ...1 HF Reader System Series 6000 S6350 Multi Protocol Reader Modules RI STU TRDC 01 02 Reference Guide 11 06 21 700 September 2001 A TEXAS INSTRUMENTS TECHNOLOGY...

Page 2: ...ing to systems or applications incorporating TI products In addition TI assumes no liability and is not responsible for infringement of patents and or any other intellectual or industrial property rig...

Page 3: ...rovided in Chapter 4 Conventions The following pictograms and designations are used in the operating instructions WARNING A WARNING IS USED WHERE CARE MUST BE TAKEN OR A CERTAIN PROCEDURE MUST BE FOLL...

Page 4: ...nearest TI RFID Systems Sales and Application Center The contact addresses can be found on our home page http www ti rfid com Numerical Representations Unless otherwise noted numbers are represented...

Page 5: ...14 2 2 2 RI STU TRDC 02 with 16 pin Straight Header Connector 15 Chapter 3 Reader Protocol 16 3 1 Serial Protocol Definition 17 3 1 1 Request Packet Format Host to Reader 17 3 1 2 Response Packet For...

Page 6: ...September 2001 S6350 Reader Reference Guide 6 Introduction Topic Page 1 1 Description 7 1 1 1 Programming Interface 7 1 2 Summary of Chapters and Appendixes 7 Chapter 1...

Page 7: ...cturers Figure 1 S6350 High Frequency Reader 1 1 1 Programming Interface The S6350 Reader is designed to operate as a part of a host based reader system which essentially relegates the reader to be a...

Page 8: ...nput output pins CN1 pins 3 and 4 10 2 1 6 Baseband receiver 11 2 1 7 Connector Details 11 2 1 8 16 pin Header Connector CN1 11 2 1 9 RI STU TRDC 01 CN1 Pin Assignments 12 2 1 10 RI STU TRDC 02 CN1 Pi...

Page 9: ...C Thermal shock 40 o C to 85 o C using MIL STD 810E Method 503 3 for 100 cycles duration 30 minutes per temperature Mechanical shock 5 Gs at 10 ms half sinusoidal waves 6 axes MIL STD 801E Method 516...

Page 10: ...utput pins CN1 pins 3 and 4 Pins 3 and 4 on CN1 may be configured by software commands to read a logic level input or to switch an external load to ground no pull up is provided Figure 2 Example Circu...

Page 11: ...omponent side for the RI STU TRDC 01 The details and orientation of each connector pin are provided in the following tables 2 1 8 16 pin Header Connector CN1 Pin Function 1 0 Volts 2 5 Volts 3 Open co...

Page 12: ...September 2001 S6350 Reader Reference Guide 12 2 1 9 RI STU TRDC 01 CN1 Pin Assignments 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 Figure 3 16 pin Right Angle Header Connector CN1 1 Component Side PCB PCB...

Page 13: ...ember 2001 S6350 Reader Reference Guide 13 2 1 10 RI STU TRDC 02 CN1 Pin Assignments 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 Figure 4 16 pin Header Connector CN1 viewed from component side COMPONENT SI...

Page 14: ...September 2001 S6350 Reader Reference Guide 14 2 2 Mechanical Specifications 2 2 1 RI STU TRDC 01 with 16 pin Right Angle Connector Figure 5 Note All dimensions are in metric...

Page 15: ...September 2001 S6350 Reader Reference Guide 15 2 2 2 RI STU TRDC 02 with 16 pin Straight Header Connector Figure 6 Note All dimensions are in inches COMPONENT SIDE...

Page 16: ...ommand Flags Response 19 3 1 5 BCC 19 3 1 6 Example Request Packet 19 3 2 Command Definitions 20 3 2 1 Tag it HF Command Definitions 20 3 2 2 Miscellaneous Commands 23 3 2 3 ISO IEC FCD 15693 Part 3 T...

Page 17: ...rpose Start of Frame Field Name Length Field Size 2 byte LSB first Field Value Packet dependent Purpose Describes the length of the whole packet including SOF Field Name Node Address Field Size 2 byte...

Page 18: ...ies the action just taken by the reader Field Name Data Field Size 0 to 23 bytes Field Value Command dependent Purpose Contains the parameters and data for the command just processed Field Name BCC Fi...

Page 19: ...C is used for error detection and is attached to the end of the packet The 16 bit BCC is calculated on all the bytes of the packet including the SOF The BCC consists of two parts the LSbyte is a Longi...

Page 20: ...ction containing the data received from the transponder LSbyte first followed by a single byte indicating the lock status and then another single byte containing the block address The two LSB s of the...

Page 21: ...section Example Read the details of a Tag it TM transponder non address Request packet 01 09 00 00 00 00 05 0D F2hex The response packet is similar to the request packet with the data section containi...

Page 22: ...icating the lock status and then another single byte containing the block address Block 7 data if selected followed by a single byte indicating the lock status and then another single byte containing...

Page 23: ...DB 24hex FLASH loader initialised and control transferred Send Data to FLASH Command D8hex This command is used to load data into the FLASH memory Example Request packet 01 8D 00 00 00 00 D8 132 byte...

Page 24: ...reader inputs Request packet 01 09 00 00 00 00 F1 F9 06hex The response packet is similar to the request packet with the data section containing a byte representing the state of the inputs Bit 0 of th...

Page 25: ...sful RF Carrier on off Command F4hex Switches the RF carrier on or off The data section contains one byte FFhex to turn the carrier on or 00hex to turn the carrier off Example Switch the carrier on Re...

Page 26: ...able 3 2 3 1 ISO IEC 15693 3 Command Codes Command Function Command Code Inventory Mandatory Command 01hex Stay Quiet Mandatory Command 02hex Read Single Block 20hex Write Single Block 21hex Lock Bloc...

Page 27: ...oding Mode 1 256 Request Packet Format for ISO IEC 15693 3 The request packet consists of the header packet length node address command flags reader command 60hex ISO IEC 15693 3 command data bytes 0...

Page 28: ...for a command Checksum 2 bytes Byte 1 is an XOR checksum of all elements from the header to the last byte Response Packet Format for ISO IEC 15693 3 Similar to the request packet the response packet...

Page 29: ...Length 2 bytes Defines the length of the packet including checksum Node Address 2 bytes Defines the Node address of the reader Response Flags 1 byte Defines the response of the reader to the request B...

Page 30: ...md Flag Cmd Config Byte Data Check sum 01hex 2 bytes 2 bytes 1 byte 60hex Byte 0 bytes 1 n 2 bytes ISO Inventory Request Format SOF Flags Inventory Command Opt AFI Mask Length Mask Value CRC16 EOF Not...

Page 31: ...6 respectively A set bit corresponds to a collision being detected in that particular Time Slot Note It is possible to issue the Inventory Command for just 1 Time Slot instead of 16 In this case the p...

Page 32: ...Address Cmd Flag Cmd Config Byte Data Check sum 01hex 2 bytes 2 bytes 1 byte 60hex Byte 0 bytes 1 n 2 bytes ISO Stay Quiet Request Format SOF Flags Stay Quiet Command UID CRC16 EOF Not Used 1 byte O2...

Page 33: ...Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byte 60hex bytes 0 m 2 bytes Response when Error_flag is set SOF Flags Error Code CRC16 EOF Not Used 1 byte 1 byte Not Used Not Used OR R...

Page 34: ...EOF Not Used 1 byte 21hex 8 bytes 1 byte Not Used Not Used ISO Write Single Block Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 byt...

Page 35: ...Used 1 byte 22hex 8 bytes 1 byte Not Used Not Used ISO Lock Block Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byt...

Page 36: ...ID 1 st Block of blocks CRC1 6 EOF Not Used 1 byte 23hex 8 bytes 1 byte 1 byte Not Used Not Used ISO Read Multiple Blocks Response Packet ISO Response Data Header Packet Length Node Address Response F...

Page 37: ...1 byte 27hex 8 bytes 1 byte Not Used Not Used ISO Write AFI Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byte 60he...

Page 38: ...byte 28hex 8 bytes 1 byte Not Used Not Used ISO Lock AFI Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byte 60hex b...

Page 39: ...ed 1 byte 29hex 8 bytes 1 byte Not Used Not Used ISO Write DSFID Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byte...

Page 40: ...ed 1 byte 2Ahex 8 bytes Not Used Not Used ISO Lock DSFID Response Packet ISO Response Data Header Packet Length Node Address Response Flags Command Data Check sum 01hex 2 bytes 2 bytes 1 byte 60hex by...

Page 41: ...le Block Security Status UID 1 st Block of Blocks CRC16 EOF Not Used 1 byte 2Chex 8 bytes 8 bytes Not Used Not Used ISO Get Multiple Block Security Status Response Packet ISO Response Data Header Pack...

Page 42: ...42 Regulatory and Warranty Notices Topic Page 4 1 FCC Conformity 43 4 2 ETSI Conformity 43 4 3 CE Conformity 43 4 4 Warranty and Liability 43 Chapter 4...

Page 43: ...d to obtain approvals as required from the local authorities before operating or selling this system 4 3 CE Conformity Any device or system incorporating the S 6350 reader in full or in part may need...

Page 44: ...sion Command F0hex The boot loader only operates at 57600 baud with 8 data bits 1 start bit 1 stop bit and no parity The application firmware will always accept the Initiate FLASH Loader Command D0 he...

Page 45: ...er not found 02hex Command not supported 03hex Packet BCC invalid 04hex Packet flags invalid for command 05hex General write failure 06hex Write failure due to locked block 07hex Transponder does not...