SBOA103C
Jan 2006
PGA309 Quick Start
System Reference Guide
55
Step B
Make sure the
PGA309 Test Pin
High
box is not checked. When in
this mode the PGA309 will read the
EEPROM and adjust offset and
gain for each temperature
conversion
Step D
Press the
Read PGA309
to see
the updated register values.
After Step D, the initial
calibration is complete.
Step C
Press
Write EEPROM
to
store the lookup table in
the external EEPROM .
Step A
Press the
Open File
button to get the file
containing the
calibration results.