Software
28
SLDU031 – December 2017
Copyright © 2017, Texas Instruments Incorporated
PGAxxxEVM-037 Pressure Sensor Signal Conditioner Evaluation Module
4.14 Data Monitor Page
Figure 20. Data Monitor Page
The
Data Monitor
page (see
) allows you to see the ADC sample values being read in real time.
Data can be read from the P Channel, the T Channel, or both on the same graph. The number of samples
recorded can be adjusted from 128 to 4096. By default, the graph will continually loop until it is stopped by
the user, but by unchecking the
Loop
checkbox the samples will stop when the record length is reached.
Data can be exported to a .txt file format by clicking the
Export Data
button. The file contains all of the
data currently displayed in the plot in a comma separated value format with the sample number, the P
channel value, and the T channel value for each sample for easy data manipulation.