Texas Instruments OPT3006 User Manual Download Page 25

IMPORTANT NOTICE

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.

TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.

TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.

TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.

Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.

Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.

Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.

In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.

No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.

Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have

not

been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and

regulatory requirements in connection with such use.

TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.

Products

Applications

Audio

www.ti.com/audio

Automotive and Transportation

www.ti.com/automotive

Amplifiers

amplifier.ti.com

Communications and Telecom

www.ti.com/communications

Data Converters

dataconverter.ti.com

Computers and Peripherals

www.ti.com/computers

DLP® Products

www.dlp.com

Consumer Electronics

www.ti.com/consumer-apps

DSP

dsp.ti.com

Energy and Lighting

www.ti.com/energy

Clocks and Timers

www.ti.com/clocks

Industrial

www.ti.com/industrial

Interface

interface.ti.com

Medical

www.ti.com/medical

Logic

logic.ti.com

Security

www.ti.com/security

Power Mgmt

power.ti.com

Space, Avionics and Defense

www.ti.com/space-avionics-defense

Microcontrollers

microcontroller.ti.com

Video and Imaging

www.ti.com/video

RFID

www.ti-rfid.com

OMAP Applications Processors

www.ti.com/omap

TI E2E Community

e2e.ti.com

Wireless Connectivity

www.ti.com/wirelessconnectivity

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2016, Texas Instruments Incorporated

Summary of Contents for OPT3006

Page 1: ...ftware and hardware and reviews various aspects of the program operation Throughout this document the terms evaluation board evaluation module and EVM are synonymous with the OPT3006EVM This document...

Page 2: ...corded Values 12 14 Register x01 Control and Status Register Bits 12 15 Registers x02 and x03 Lux Limit Controls 12 16 Simulated Screen Backlight Dimmer 12 17 Lux vs Sample Number Plot 13 18 Re Initia...

Page 3: ...T3006 device under various conditions The OPT3006EVM consists of two PCBs The first PCB is the SM USB DIG Platform that communicates with the computer provides power and sends and receives appropriate...

Page 4: ...ture number SBOU181 Any letter appended to the literature number corresponds to the document revision that is current at the time of the writing of this document The latest revision can be found by cl...

Page 5: ...he OPT3006EVM The computer runs the graphical user interface GUI software that communicates with the SM USB DIG Platform over a USB connection The SM USB DIG Platform translates the USB commands from...

Page 6: ...ains connections for the power I2 C and an interrupt signal For evaluation purposes the board also has a 5 pin header that allows the OPT3006EVM to be connected to hardware other than the SM USB DIG P...

Page 7: ...e connectors are misaligned Figure 4 Typical Hardware Connection Figure 5 shows the typical response when the SM USB DIG is plugged into the USB port of the computer for the first time Typically the c...

Page 8: ...oftware has been tested on the Windows 7 operating system OS with United States regional settings The software should function correctly on other Windows operating systems 3 2 Software Installation Th...

Page 9: ...porated OPT3006EVM User s Guide The OPT3006EVM software then begins the installation process as shown in Figure 7 Figure 7 Software Installation Launch Follow the prompts as shown in Figure 8 to insta...

Page 10: ...nch the EVM GUI software from the Windows Start menu It is located in a folder titled OPT3006EVM The software launches with a screen similar to that shown in Figure 9 Figure 9 Main Operation Screen If...

Page 11: ...rating check to see that the power to the device is turned on by looking at the LED on the SM USB DIG Platform and at the VDUT indicator on the SM USB DIG tab in the GUI software as shown in Figure 11...

Page 12: ...the Lux Full Scale Range selection field has four identical automatic range modes 0x0C 0x0F Also the Mode selection field has two identical continuous sampling options 0x02 and 0x03 Figure 14 Registe...

Page 13: ...7 As readings are collected the plot is updated with those values The y axis is autoscaled to show the magnitude of the lux value recorded and has a visible history of 100 samples along the x axis The...

Page 14: ...file is selected by clicking Select a File Path turning on the Logging On Off selector switch appends data to that file in tab format Figure 19 Data Logging Setup and Enable Under the final tab Regis...

Page 15: ...l a wire to the pad or via and then to the appropriate signal source Figure 21 OPT3006EVM Schematic Including MHR046 FPCB An OPT3006 with no electrical connection marked with Non Functional Mechanical...

Page 16: ...out and Bill of Materials www ti com 16 SBOU181 October 2016 Submit Documentation Feedback Copyright 2016 Texas Instruments Incorporated OPT3006EVM User s Guide Figure 22 FPCB MHRS046 Schematic Contai...

Page 17: ...Documentation Feedback Copyright 2016 Texas Instruments Incorporated OPT3006EVM User s Guide 4 2 PCB Layout Figure 23 and Figure 24 show the assembly drawings of the top and bottom PCB layers respect...

Page 18: ...SBOU181 October 2016 Submit Documentation Feedback Copyright 2016 Texas Instruments Incorporated OPT3006EVM User s Guide Figure 25 and Figure 26 show the top and bottom PCB layers of the EVM respecti...

Page 19: ...k Copyright 2016 Texas Instruments Incorporated OPT3006EVM User s Guide Figure 27 and Figure 28 show the top and bottom layers of the MHR046 FPCB respectively Figure 29 shows the FPCB assembly drawing...

Page 20: ...tion Part Number MFR 1 C1 CAP CERM 0 1uF 50V 10 X7R 0805 08055C104KAT2A AVX Corp 1 J1 Receptacle 50mil 10x1 R A TH 851 43 010 20 001000 Mill Max 1 R1 RES 0 ohm 5 0 125W 0805 CRCW08050000Z0EA Vishay Da...

Page 21: ...are returned during the warranty period to the address designated by TI and that are determined by TI not to conform to such warranty If TI elects to repair or replace such EVM TI shall have a reasona...

Page 22: ...transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indic...

Page 23: ...ified allowable ranges some circuit components may have elevated case temperatures These components include but are not limited to linear regulators switching transistors pass transistors current sens...

Page 24: ...REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF USE L...

Page 25: ...sponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related inf...

Reviews: