1
5
2
3
4
www.ti.com
Demo Examples
6.4
Demo 4: OTP Transponder (Read or Write ID) – Tab 2
Figure 13. Read or Write ID of OTP Transponder
1
Click on Read ID (or) Write ID buttons to read (or) write the 64 byte ID with 16 byte CRC to an OTP
transponder.
2
This is the 10 byte data (8 byte ID and 2 byte CRC) of the OTP Transponder shown in grid view
table first row. The Lock column on the right side of the transponder data shows the lock stats of
the ID. To lock the transponder check the Lock box and click Write ID.
3
Decimal field for ISO 11785 animal or industrial code. This automatically converts to 8 byte hex
data in field 2. If hex data is entered in field 2, data automatically converts to decimal data in field 3.
4
Auto increment the ID after successful programming of a transponder.
5
Loads a list of IDs from an Excel® spreadsheet to write a batch of transponders. The Auto Inc ID
checkbox at position 4 needs to be checked to load the subsequent ID from the Excel spreadsheet
after each successful write to the transponder. Click Unload XLS to remove the loaded data.
13
SCBU050 – July 2012
MRD2EVM Microreader Evaluation Kit
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated