Appendix D
17
SNAU219 – June 2017
Copyright © 2017, Texas Instruments Incorporated
Changing Reference Oscillator and Setup
For single-ended:
1. Switch R24b to R24.
2. Switch R29b to R29
3. Must remove R33 to remove power from oscillator
4. Populate R25 and R30.
5. Remove R32
Figure 15. Differential Reference Configuration