Device Configuration
4.2.11
OUT0 and OUT1 Mode Selection
The LMH0318 75-
Ω
OUT0 and 50-
Ω
OUT1 can be configured to drive out the reclocked data, raw data
(i.e non reclocked), clock, or these outputs to be muted (common mode voltage on both positive and
negative output signal).
4.2.11.1
OUT0 and OUT1 Default Mode of Operation
In default mode, register 0x1C[3:2] determine the output configuration for both outputs per following table.
0x1C[3:2}
OUT0
OUT1
00
Mute
Mute
01
Locked: Reclocked Data
Full data rate clock
Unlocked: Raw Data
Unlocked: Mute
10
Locked: Reclocked Data
Locked: Reclocked Data
Unlocked: Raw Data
Unlocked: Raw Data
11
Forced Raw Data
Forced Raw Data
The following can be used to set OUT0 and OUT1 configuration:
RAW
FF
04
07
//Select Channel Registers
RAW
09
00
20
//Allow register 0x1C to control OUT0 and OUT1 configuration
RAW
1C
00
0C
//Mute OUT0 and OUT1
RAW
1C
04
0C
//Locked: OUT0 Reclocked Data OUT1 Recovered Clock Un-Locked: OUT0
Raw Data OUT1 Mute
RAW
1C
80
0C
//Locked: OUT0: Reclocked Data OUT1: Reclocked Data Un-Locked: OUT0
Raw Data OUT1 Raw data
RAW
1C
0C
0C
//OUT0 Raw Data OUT1 Raw Data