Schematic
3
SLVUBM3B – January 2019 – Revised December 2019
Copyright © 2019, Texas Instruments Incorporated
LM76202-Q1 Evaluation Module
3
Schematic
provides the schematic for LM76202-Q1EVM.
Do not use R9 between OVP and GND. For Programmable OV clamp, see
in the
Figure 1. LM76202-Q1EVM Schematic
4
Connector, Jumper and LED Descriptions
4.1
Input and Output Connector Description
Table 2. Input and Output Connector Description
Connector
Label
Description
T1
VIN1
Power input connector for connecting power supply.
T2
VOUT1
Power output connector for connecting load.
4.1.1
Test Points Description
Table 3. Test Points Description
Test Points
Label
Description
TP1
FLT
FLT Signal output
TP2
VIN1
Positive voltage input
TP3
VOUT1
Positive voltage output
TP6
RTN1
RTN signal
TP7
GND
Input ground signal
TP8
GND
Output ground signal
Table 4. Jumper Description
Jumper
Label
Description
J1
Pull-up for FLT
This jumper is used for pulling up FLT to VOUT.
OPEN
: For pulling-up FLT with any other voltage (like VIN), Open this jumper and connect
Pin 2 of J1 externally to the desired voltage (< 60 V).
CLOSED
: FLT is pulled-up from VOUT.
J2
UVLO Selection
This jumper is used for selecting UVLO input
1-2:
UVLO configured through R2 and R5 resistors. Close Jumper J6 with this configuration.
2-3
: UVLO set to 4-V (POR). Open Jumper J6 with this configuration.
J3
VOUT Indication
Close this jumper for powering D4(Green) LED from VOUT