Quick Start Guide
Table 3-2. Description of Switch Configuration and Settings (continued)
Component
Switch No.
Name and Description
SCL
2
ON
for SMBus modes
OFF for Pin mode
SW4
SDA
1
ON
for SMBus modes
OFF for Pin mode
[Pin mode] VODB1: VOD Control [1] for B-Channels
6-5-4
[SMBus modes] AD1: ADDR[1]
SW5
[Pin mode] VODB0: VOD Control [0] for B-Channels
3-2-1
[SMBus modes] AD0: ADDR[0]
[Pin and SMBus modes] LPBK-RES (RES1): Reserved
6-5-4
Note: Set all switches to OFF for normal operation.
[Pin and SMBus slave mode] SD_TH: Signal detect assert/de-assert
SW6
Threshold level for signal detect monitor
3-2-1
[SMBus master mode] READ_EN: See description of Read Enable button
on SW10.
RESET/PWDN
2
ON
to enable device
OFF to disable device
SW7
VDD_SEL
1
ON
for 3.3 V mode
OFF for 2.5 V mode
[Pin and SMBus modes] RES3: Reserved
6-5-4
Note: In Pin mode, this must be tied to GND (6-5-4 =
ON
-OFF-OFF)
SW8
[Pin mode] EQA: 4-level EQ settings for A-Channels
3-2-1
[SMBus modes] Set all switches to OFF. EQA is controlled individually via
registers.
[Pin and SMBus modes] RES2: Reserved
6-5-4
Note: Set all switches to OFF for normal operation.
SW9
[Pin and SMBus modes] RX_DET: Enable or disable the internal 50
Ω
to
3-2-1
VDD Input Termination. See datasheet for more information.
[SMBus master mode] READ_EN: Enable load from external EEPROM in
master mode
SW6: SD_TH (3-2-1) becomes the READ_EN pin.
SW10
N/A
To start the loading at power up, set SW6 pin 3 to
ON
(pull to GND).
To control the start manually, set SW6 pin 1 to
ON
(pull to VDD) and push
the SW10 button for the high-to-low transition to start the loading. When
loading is complete, the LED – D1 will turn off.
3.1
Quick Start Guide
1. Connect J19: V
IN
= 3.3 V or V
DD
= 2.5 V and GND.
•
For V
IN
= 3.3 V: Set SW7 pin1 (VDD_SEL) to the
ON
position (enable internal LDO regulator) and
float V
DD
at J19.
•
For V
IN
= 2.5 V: Set SW7 pin1 (VDD_SEL) to the OFF positions (disable internal LDO regulator)
and float V
IN
at J19.
2. Set Jumper J20 for V
IH
connection to V
IN
or V
DD
.
•
For 3.3 V mode: V
IH
tied to V
IN
(see
)
•
For 2.5 V mode: V
IH
tied to V
DD
(see
)
3. Set the control switches for normal operation:
9
SNLU171 – September 2014
DS80PCI810EVM Configuration Overview
Copyright © 2014, Texas Instruments Incorporated