User Interface
www.ti.com
10
SLVUB95C – December 2017 – Revised August 2018
Submit Documentation Feedback
Copyright © 2017–2018, Texas Instruments Incorporated
DRV10974 Evaluation Module
6
User Interface
6.1
Jumpers
Descriptions for the jumpers are provided in the following list:
Figure 8. CS Receptacle (J10)
•
CS
(J10) is the
current limit
setting. CS connects a resistor to GND for current-limit setting. This
receptacle is meant for easy implementation of axial-lead through-hole resistors. Otherwise, R4 can be
used for substitution of surface-mount resistors.
Figure 9. ADV Receptacle (J8)
•
ADV
(J8) is the
lead angle
setting. ADV connects a resistor to GND for lead angle setting. This
receptacle is meant for easy implementation of axial-lead through-hole resistors. Otherwise, R2 can be
used for substitution of surface-mount resistors.
Figure 10. RMP Receptacle (J9)
•
RMP
(J9) is the
acceleration ramp-rate control
setting. RMP connects a resistor to GND for setting the
acceleration ramp-rate control. This receptacle is meant for easy implementation of axial-lead through-
hole resistors. Otherwise, R3 can be used for substitution of surface-mount resistors.