Texas Instruments bq34110EVM-796 User Manual Download Page 5

www.ti.com

bq34110EVM Quick Start Guide

5

SLUUBI1A – October 2016 – Revised July 2018

Submit Documentation Feedback

Copyright © 2016–2018, Texas Instruments Incorporated

bq34110EVM-796 Evaluation Module

I2C communication port (J1): I2C bus

Attach the communications interface adapter cable to J1 and to the I2C port on the EV2400.

Chip Enable

(J4): CE

Place a jumper on CE enabling the REG25 regulator to power the bq34110.

External Learning Load

: LOAD jumper and J8.

The external learning load can be configured using the on-board 20-

Ω

load resistor or an external

resistor attached to J8. The 20-

Ω

resistor can support a 2000-mAh single-cell configuration. Other

configurations require that a resistor be attached to J8. The LOAD jumper must be removed when
using the external load resistor.

ALERT1, ALERT2 (J6)

Place jumpers on J4 PU1 and PU2 to apply pull-up resistors to open drain outputs ALERT1 and
ALERT2. Monitor the outputs monitored on J6.

2.5.3

Pin Description

Table 4

lists the EVM pin descriptions.

Table 4. EVM Pin Descriptions

Pin Name

Description

ALERT1

Open drain alert output

ALERT2

Open drain alert output

BAT+

Battery stack positive terminal

BAT–

Battery stack negative terminal

CE

Chip Enable

GND

Ground return

LEN

Optional LEN GPIO

PACK–

Pack negative terminal

OPT EXT LOAD

Connection to apply an external learning load

SCL

I

2

C clock signal

SDA

I

2

C data signal

VEN

Optional VEN GPIO. When set, this pin is used to control the external voltage
divider for the BAT pin and disables the internal voltage divider.

2.6

PC Interface Connection

The following steps configure the hardware for interfacing with the PC:

1. Connect the bq34110 EVM to the EV2400 using wire leads as shown in

Table 3

.

2. Connect the PC USB cable to the EV2400 and the PC USB port.

Table 5. Circuit Module to EV2400 Connections

bq34110EVM

EV2300

EV2400

SDA

SDA

PORT2 - SDA

SCL

SCL

PORT2 - SCL

VSS

GND

PORT2 - VSS

The bq34110EVM-796 is now set up for operation.

Summary of Contents for bq34110EVM-796

Page 1: ...on Evaluate the overall functionality under different charge and discharge conditions Contents 1 Features 2 1 1 Kit Contents 2 1 2 Ordering Information 2 1 3 bq34110 Circuits Module Performance Specif...

Page 2: ...module for quick setup Personal computer PC software and interface board for easy evaluation Software allows data logging for system analysis 1 1 Kit Contents The following items are included in the...

Page 3: ...ing the evaluation software connect the EV2400 to the PC using the USB cable The EV2400 driver will install automatically 2 3 EV2400 Firmware Updater The EV2400 firmware is updated periodically The bq...

Page 4: ...ange for your pack Table 3 Cell Configuration Jumper Placement Cell Configuration Jumper Placement J2 Single cell or stack voltage less than 5 V Place jumpers in the 5 V positions Multicell Place jump...

Page 5: ...drain outputs ALERT1 and ALERT2 Monitor the outputs monitored on J6 2 5 3 Pin Description Table 4 lists the EVM pin descriptions Table 4 EVM Pin Descriptions Pin Name Description ALERT1 Open drain al...

Page 6: ...n or Refresh single time scan buttons can be clicked in order to update the data in the Registers and Data Memory windows bqStudio provides a logging function which logs selected Data Registers last r...

Page 7: ...To read all the data from the bq34110 non volatile flash memory click on the Read All button on the Data Memory window Make sure the device is not sealed and in full access to read or write to the dat...

Page 8: ...2 5 V by providing an external 3 3 V supply to power REGIN For voltages below 2 5V remove the jumper from J2 pins 3 and 4 upper 5 V jumper location and apply a 3 3 V supply to the REGIN test point Fo...

Page 9: ...alue in the Applied Voltage field and select the Calibrate Voltage box Press the Calibrate Gas Gauge button to calibrate the voltage measurement system Deselect the Calibrate Voltage boxes after volta...

Page 10: ...n to calibrate Verify whether the current reports 0 mA Connect a 2 A load from BAT to PACK Enter 2000 in the Applied Current field and select the Calibrate Current box Press the Calibrate Gas Gauge bu...

Page 11: ...m I2C window This tool provides access to parameters using I2 C and Manufacturing Access commands see Figure 6 Figure 6 Advanced Comm I2 C Screen Examples Reading an I2 C Command Read SBData Voltage 0...

Page 12: ...rt the device firmware as an srec bq fs and df fs files Figure 7 Golden Image Window 3 6 1 Exporting the Flash Memory The srec file contains the full flash memory The bq fs contains the program memory...

Page 13: ...sed to obtain the experimental data needed to calculate the CEDV coefficients Figure 8 CEDV Coefficients Calculation Flow The equipment necessary is as follows bqStudio software bq34110EVM 796 Power s...

Page 14: ...s Incorporated bq34110EVM 796 Evaluation Module 4 Circuit Module Physical Layout Bill of Materials and Schematic This section contains the board layout bill of materials and schematic for the bq34110...

Page 15: ...hysical Layout Bill of Materials and Schematic 15 SLUUBI1A October 2016 Revised July 2018 Submit Documentation Feedback Copyright 2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation Mod...

Page 16: ...ayout Bill of Materials and Schematic www ti com 16 SLUUBI1A October 2016 Revised July 2018 Submit Documentation Feedback Copyright 2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation M...

Page 17: ...hysical Layout Bill of Materials and Schematic 17 SLUUBI1A October 2016 Revised July 2018 Submit Documentation Feedback Copyright 2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation Mod...

Page 18: ...k 3 5 mm 2x1 Tin TH Terminal Block 3 5 mm 2x1 TH 39357 0002 Molex 1 Q1 60V MOSFET N CH 60 V 0 17 A SOT 23 SOT 23 2N7002 7 F Diodes Inc 1 Q2 50V MOSFET P CH 50 V 0 13 A SOT 323 SOT 323 BSS84W 7 F Diode...

Page 19: ...2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation Module Table 6 Bill of Materials continued Qty Reference Designator Value Description Size Part Number Manufacturer 2 U2 U3 ESD in 0...

Page 20: ...www ti com 20 SLUUBI1A October 2016 Revised July 2018 Submit Documentation Feedback Copyright 2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation Module 4 3 Schematic Figure 13 illustr...

Page 21: ...entation Feedback Copyright 2016 2018 Texas Instruments Incorporated bq34110EVM 796 Evaluation Module 5 Related Documentation from Texas Instruments bq34110 data sheet bq34110 Multi Chemistry CEDV Bat...

Page 22: ...ge and example to show the transaction log 1 Added additional jumper settings descriptions within the schematic image 2 Changed Quick Start Guide to include steps to set up EV2400 firmware and bq34110...

Page 23: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Page 24: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments BQ34110EVM 796...

Reviews: