Operation
10
SLUUBI1A – October 2016 – Revised July 2018
Copyright © 2016–2018, Texas Instruments Incorporated
bq34110EVM-796 Evaluation Module
3.3.3
Current Calibration
The gauge offers
CC Offset
and
Board Offset
calibration options to zero any residual current that may be
reported by the gauge. These calibrations are only required if the gauge does not report 0-mA current
when no current should be present.
•
Select the
CC Offset
calibration option.
•
Press the
Calibrate Gas Gauge
button to calibrate.
•
Verify whether the current reports 0 mA. Proceed with the
Board Offset Current
calibration if current is
reported.
•
Select the
CC Offset
calibration option.
•
Press the
Calibrate Gas Gauge
button to calibrate.
•
Verify whether the current reports 0 mA.
•
Connect a 2-A load from BAT+ to PACK–.
•
Enter –2000 in the
Applied Current
field and select the
Calibrate Current
box.
•
Press the
Calibrate Gas Gauge
button to calibrate.
•
Deselect the
Calibrate Current
box after current calibration has completed.
3.4
Programming Screen
Press the
Programming
button to select the
Programming Update
window (
). This window allows
the user to import the device firmware.
Figure 5. Programming Screen
3.4.1
Programming the Flash Memory
The
Programming
screen is used to initialize the device by loading the default .srec into the flash memory
(see
•
Search for the .srec file using the
Browse
button.
•
Press the
Program
button and wait for the download to complete.
•
Press the
Execute FW
button after the programming has been completed.
–
Press the
Read Srec
button to save the flash memory contents to the file. Wait for the download to
complete.