2 Test Summary

2.1 Definitions

This procedure details how to configure the BMS035 evaluation board. For the test procedure, the following
naming conventions are followed. Refer to the 

BMS035 schematic

 for details.

VXXX:

External voltage supply name (VADP, VBT, VSBT)

LOADW:

External load name (LOADR, LOADI)

V(TPyyy):

Voltage at internal test point TPyyy. For example, V(TP12) means the voltage at TP12.

V(Jxx):

Voltage at jack terminal Jxx.

V(TP(XXX)):

Voltage at test point “XXX”. For example, V(ACDET) means the voltage at the test point which is
marked as “ACDET”.

V(XXX, YYY):

Voltage across point XXX and YYY.

I(JXX(YYY)):

Current going out from the YYY terminal of jack XX.

Jxx(BBB):

Terminal or pin BBB of jack xx

Jxx ON :

Internal jumper Jxx terminals are shorted

Jxx OFF:

Internal jumper Jxx terminals are open

Jxx (-YY-) ON:

Internal jumper Jxx adjacent terminals marked as “YY” are shorted

Measure: → A,B

Check specified parameters A, B. If measured values are not within specified limits, the unit under test
has failed.

Observe → A,B

Observe if A, B occurs. If they do not occur, the unit under test has failed.

Assembly drawings

 have locations for jumpers, test points, and individual components.

2.2 Equipment

The following list of equipment is required for fully testing the EVM:

1.

Power Supplies

A power supply capable of supplying 26 V at 6 A is required. While this part can handle larger voltage and
current, it is not necessary for this procedure.

2.

Load #1

A 20-V, 6-A system DC electronic load and setting as constant voltage load mode.

3.

Load #2

A Kepco load: BOP36-6M, DC 0 to ±36 V, 0 to ±6 A (or higher), or equivalent.

4.

Meters

Six Fluke 75 multimeters, (equivalent or better) or: Three equivalent voltage meters and three equivalent
current meters.

5.

Computer

A computer with at least one USB port and a USB cable.

6.

EV2400 Communication Kit

7.

Software

Download and properly install bqStudio from 

https://www.ti.com/tool/BQSTUDIO

.

www.ti.com

Test Summary

SLUUC74 – MAY 2021

Submit Document Feedback

BQ25720, BQ25723 Evaluation Module

5

Copyright © 2021 Texas Instruments Incorporated

Summary of Contents for BQ25720

Page 1: ...2 Board Assembly Layout 12 3 3 Schematic 18 List of Figures Figure 2 2 Original Test Setup for BMS035 BQ2572x EVM 7 Figure 2 3 Main Window of the BQ2572x Evaluation Software 8 Figure 2 4 EN_OTG 9 Fig...

Page 2: ...72x is a synchronous NVDC 1 battery buck boost charge controller offering a low component count high efficiency solution for space constrained multi chemistry battery charging applications The NVDC 1...

Page 3: ...ription Factory Setting JP1 Bypass inrush control circuit spa JP1 on bypasses input FETs Q6 and Q7 external selector spa JP1 off CHRG_OK controls Q6 and Q7 external selector Installed JP2 Jumper on Fo...

Page 4: ...5 5 9 15 20 26 V Battery voltage VBAT Voltage applied at VBAT terminal 0 19 2 V Supply current IAC Maximum input current from AC adapter input 0 6 4 A Output current Iout Output current 0 8 A Operati...

Page 5: ...ues are not within specified limits the unit under test has failed Observe A B Observe if A B occurs If they do not occur the unit under test has failed Assembly drawings have locations for jumpers te...

Page 6: ...5 Connect Load 2 in series with a current meter to J5 VBAT and PGND Connect a voltage meter across J5 VBAT and PGND Set 7 V at KEPCO load output Turn off load 2 Note Add a 47 F capacitor on the BAT p...

Page 7: ...ect Charger and click the Next button b For SMBus BQ25720 select Charger_1_00_BQ25720 bqz on the Select a Target Page For I2C BQ25723 select Charger_1_00_BQ25723 bqz on the Select a Target Page c Afte...

Page 8: ...ure 2 3 Main Window of the BQ2572x Evaluation Software Test Summary www ti com 8 BQ25720 BQ25723 Evaluation Module SLUUC74 MAY 2021 Submit Document Feedback Copyright 2021 Texas Instruments Incorporat...

Page 9: ...4 V 0 5 V 5 Turn on LOAD 2 VBAT Load Measure V J5 VBAT 7 V 0 5 V Measure I J5 VBAT 2 A 0 5 V 2 4 2 OTG Function Use the following for OTG function settings 1 Connect a 7 V power supply to the VBAT loa...

Page 10: ...323 SOD 323 BAT54HT1G ON Semiconductor D4 1 Green LED Green SMD 1 6x0 8x0 8mm LTST C190GKT Lite On H1 H2 H3 H4 4 Bumpon Hemisphere 0 44 X 0 20 Clear Transparent Bumpon SJ 5303 CLEAR 3M J1 J5 J6 3 Ter...

Page 11: ...est Point Multipurpose Red TH Red Multipurpose Testpoint 5010 Keystone TP8 TP31 TP39 3 Test Point Multipurpose Black TH Black Multipurpose Testpoint 5011 Keystone U1 1 SMBus I2C 1 4 Cell Narrow VDC Bu...

Page 12: ...illustrate the board assembly and layout images Figure 3 1 Top Assembly Bill of Materials Board Layout and Schematics www ti com 12 BQ25720 BQ25723 Evaluation Module SLUUC74 MAY 2021 Submit Document...

Page 13: ...re 3 2 Bottom Assembly www ti com Bill of Materials Board Layout and Schematics SLUUC74 MAY 2021 Submit Document Feedback BQ25720 BQ25723 Evaluation Module 13 Copyright 2021 Texas Instruments Incorpor...

Page 14: ...gure 3 3 PCB Layer 1 Bill of Materials Board Layout and Schematics www ti com 14 BQ25720 BQ25723 Evaluation Module SLUUC74 MAY 2021 Submit Document Feedback Copyright 2021 Texas Instruments Incorporat...

Page 15: ...gure 3 4 PCB Layer 2 www ti com Bill of Materials Board Layout and Schematics SLUUC74 MAY 2021 Submit Document Feedback BQ25720 BQ25723 Evaluation Module 15 Copyright 2021 Texas Instruments Incorporat...

Page 16: ...gure 3 5 PCB Layer 3 Bill of Materials Board Layout and Schematics www ti com 16 BQ25720 BQ25723 Evaluation Module SLUUC74 MAY 2021 Submit Document Feedback Copyright 2021 Texas Instruments Incorporat...

Page 17: ...gure 3 6 PCB Layer 4 www ti com Bill of Materials Board Layout and Schematics SLUUC74 MAY 2021 Submit Document Feedback BQ25720 BQ25723 Evaluation Module 17 Copyright 2021 Texas Instruments Incorporat...

Page 18: ...Z1 PGND 1 0 R13 VIN 4 3 2 Q9A DCX124EK 7 F 1 6 5 Q9B DCX124EK 7 F 10 0 R10 PGND 10 0k R17 3V3 7 8 1 2 3 5 6 Q7 4 7 8 1 2 3 5 6 Q6 470nF 50V C25 GND 1 2 3 4 J3 0022053041 10uF C26 300k R29 33pF C31 15...

Page 19: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 20: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 21: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 22: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 23: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 24: ...are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and...

Reviews: