lists the recommended operating conditions.
Table 1-3. Recommended Operating Conditions
Symbol
Description
MIN
TYP
MAX
Unit
Supply voltage, V
IN
Input voltage from AC adapter input
3.5
5, 9, 15, 20
26
V
Battery voltage, V
BAT
Voltage applied at VBAT terminal
0
19.2
V
Supply current, I
AC
Maximum input current from AC adapter
input
0
6.4
A
Output current, I
out
Output current
0
8
A
Operating junction temperature
range, T
J
0
125
°C
Introduction
4
BQ25720, BQ25723 Evaluation Module
SLUUC74 – MAY 2021
Copyright © 2021 Texas Instruments Incorporated