www.ti.com
Introduction
3
SLUUBT8A – June 2018 – Revised July 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
BQ2571x Evaluation Module
Table 1
lists the I/O descriptions.
Table 1. I/O Description
Jack
Description
J1–VIN
Input: positive terminal
J1–GND
Input: negative terminal (ground terminal)
J2-ILIM_control
External converter disable; logic high to pull the ILIM pin down
J2-CHRG_OK
CHRG_OK output
J2-ENZ_OTG
External OTG disable pin
J2-CELL_control
External battery removal control; logic high to pull the CELL pin down
J3–3V3
Onboard 3.3-V output
J3–SDA
SMBUS or I
2
C SDA
J3-SCL
SMBUS or I
2
C SCL
J3-GND
Ground
J4-CMPOUT
CMPOUT pin output
J4-GND
Ground
J4-CMPIN
External CMPIN pin input
J5-BAT
Connected to battery pack output
J5-GND
Ground
J6-SYS
Connected to system output
J6-GND
Ground
Table 2
displays the controls and key parameters settings.
Table 2. Controls and Key Parameters Setting
Jack
Description
Factory Setting
JP1
JP7
Inrush control setting:
spa
1. Bypass inrush control circuit
spa1.
JP1 on: bypasses input FETs Q9 and Q10 external selector
spa1.
spa1.
JP7 top two connection (pin 2 is connected to pin 3): VBUS pin on ACP
spa
2. Enable inrush control circuit
spa2.
JP1 off: CHRG_OK controls Q9 and Q10 external selector
spa2.
JP7 bottom two connection: VBUS pin on V
IN
Bypass inrush control circuit:
spa
JP1 installed
spa
JP7 top two position installed
spa
(pin2 is connected pin3)
JP2
JP3
JP4
CELL setting:
spa
1S: JP2, JP3, JP4 all open, measure CELL pin voltage 1.2 V
spa
2S: JP2 closed, JP3 and JP4 open, measure CELL pin voltage 2.7 V
spa
3S: JP3 closed, JP2 and JP4 open, measure CELL pin voltage 3.5 V
spa
4S: JP2, JP3 closed, JP4 open, measure CELL pin voltage 4.2 V Bat
spa
removal, short JP4
2S setting: JP2 installed JP3, JP4 all
open
JP5
Jumper on: Pre-bias ILIM_HIZ
Jumper off: Ground ILIM_HIZ
Installed
JP6
For input current setting:
spa
Jumper on: ILIM_HIZ LOW.
spa
Jumper off: Allow pre-bias ILIM_HIZ
Not installed
JP8
Jumper on: On-board LDO to drive the EVM 3V3
Jumper off: disconnect on-board LDO to drive the EVM 3V3
Installed