background image

Bill of Materials, Board Layout and Schematics

www.ti.com

Table 4. Bill of Materials (continued)

bq24610-001

bq24617-002

Bq24630-003

bq24616-004

Value

RefDes

Description

Size

Part Number

Mfr

1

1

1

1

5001

GND

Test Point, Black, Thru Hole Color

0.100 x 0.100

5001

Keystone

Keyed

inch

14

14

14

14

5002

/ACDRV,/BAT

Test Point, White, Thru Hole Color

0.100 x 0.100

5002

Keystone

DRV,/PG,

Keyed

inch

ACSET,CHGE
N,ISET1,ISET
2, REGN,
STAT1,STAT2
,TS,TTC,
VCC,VREF

5

5

5

5

131-4244-00

TP1,TP2,TP8,

Adaptor, 3.5-mm probe clip ( or

0.200 inch

131-4244-00

Tektronix

TP9,TP12

131-5031-00)

3

3

3

3

2N7002DICT

Q6,Q8,Q9

MOSFET, N-ch, 60V, 115mA,

SOT23

2N7002DICT

Vishay-Liteon

1.2Ohms

3

3

3

3

SI4401BDY-

Q1,Q2,Q5

MOSFET, PChan, -40V, -18A,

S0-8

SI4401BDY

Vishay-

T1-GE

(Note 5)

9.2millohm

FDS4141

Siliconxi

FDS4141

Fairchild

2

2

2

2

FDS8447

Q3,Q4

MOSFET, NChan, 40V, 50A, 4.5

S0-8

FDS8447

Vishay-

millohm

Siliconix

2

2

2

2

TP0610K

Q7,Q10

Mosfet, P-Ch, 60V, Rds 6 ohms, Id

SOT-23

TP0610K

Vishay-

185 mA

Siliconix

1

1

1

1

PCB

4 layer 2oz. PCB

HPA422

5

5

5

5

929950-00

Shorting jumpers, 2-pin, 100mil

929950-00

3M/ESD

spacing

4

4

4

4

STANDOFF M/F HEX 6-32 NYL .500"

4816

Keystone

4

4

4

4

6-32 NYL Hex nuts

NY HN 632

Building
Fasteners

10

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

SLUU396A – January 2010 – Revised July 2010

Copyright © 2010, Texas Instruments Incorporated

Summary of Contents for BQ2461X

Page 1: ...s Board Layout and Schematics 8 4 1 Bill of Materials 8 5 Board Layout 11 6 Schematics 19 List of Figures 1 Original Test Setup for HPA422 bq2461x bq2463x EVM 5 2 Top Layer 11 3 2nd Layer 12 4 3rd Lay...

Page 2: ...n The bq2461x bq2463x automatically restarts the charge cycle if the battery voltage falls below an internal threshold and enters a low quiescent current sleep mode when the input voltage falls below...

Page 3: ...n LED has no power source when off VPULLUP setting Jumper On 1 2 VPULLUP and JP3 1 2 Connect VPULLUP to VREF VREF 2 3 Connect VPULLUP to VEXT JP4 The pull up voltage source of ACDRV and BATDRV LED log...

Page 4: ...Jxx terminals are shorted Jxx OFF Internal jumper Jxx terminals are open Jxx YY ON Internal jumper Jxx adjacent terminals marked as YY are shorted Measure A B Check specified parameters A B If measure...

Page 5: ...series with a current meter multimeter to J1 VIN GND 3 Connect a voltage meter across J1 VIN GND 4 Set the power supply 2 for 0V 100mVDC 1 0 0 1A current limit and then turn off supply 5 Connect the...

Page 6: ...urn on the Load 2 Set the output voltage to 12V bq2461x or 2V bq2463x 3 Connect the output of the Load 1 in series with a current meter multimeter to J5 SYS GND Make sure a voltage meter is connected...

Page 7: ...RV off D6 BATDRV on D5 PG off D7 STAT1 off D8 STAT2 off 8 Turn off power supply 2 and 3 Set JP3 on 1 2 VPULLUP and VREF 3 PCB Layout Guideline 1 It is critical that the exposed power pad on the backsi...

Page 8: ...805 STD STD 2 2 2 2 1 0uF 50V C12 C14 Capacitor Ceramic 50V X5R 20 1206 STD STD 1 1 1 1 2 2uF 50V C2 Capacitor Ceramic 50V X7R 20 1206 STD STD 0 0 0 0 C32 Capacitor Ceramic 50V X7R 20 1206 STD STD 6 6...

Page 9: ...Std 2 2 2 2 10k R29 R30 Resistor Chip 1 16W 1 603 Std Std 6 6 6 6 100k R3 Resistor Chip 1 16W 1 603 Std Std R20 R32 R33 R37 R38 1 1 1 1 10k R16 Resistor Chip 1 10W 1 805 Std Std 1 1 1 1 100k R15 Resi...

Page 10: ...2N7002DICT Q6 Q8 Q9 MOSFET N ch 60V 115mA SOT23 2N7002DICT Vishay Liteon 1 2Ohms 3 3 3 3 SI4401BDY Q1 Q2 Q5 MOSFET PChan 40V 18A S0 8 SI4401BDY Vishay T1 GE Note 5 9 2millohm FDS4141 Siliconxi FDS414...

Page 11: ...om Board Layout 5 Board Layout Figure 2 Top Layer 11 SLUU396A January 2010 Revised July 2010 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger Copyright 2010 Texas Instruments Inco...

Page 12: ...oard Layout www ti com Figure 3 2nd Layer 12 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger SLUU396A January 2010 Revised July 2010 Copyright 2010 Texas Instruments Incorporated...

Page 13: ...ww ti com Board Layout Figure 4 3rd Layer 13 SLUU396A January 2010 Revised July 2010 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger Copyright 2010 Texas Instruments Incorporated...

Page 14: ...ard Layout www ti com Figure 5 Bottom Layer 14 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger SLUU396A January 2010 Revised July 2010 Copyright 2010 Texas Instruments Incorporat...

Page 15: ...w ti com Board Layout Figure 6 Top Assembly 15 SLUU396A January 2010 Revised July 2010 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger Copyright 2010 Texas Instruments Incorporat...

Page 16: ...d Layout www ti com Figure 7 Bottom Assembly 16 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger SLUU396A January 2010 Revised July 2010 Copyright 2010 Texas Instruments Incorpora...

Page 17: ...ti com Board Layout Figure 8 Top Silkscreen 17 SLUU396A January 2010 Revised July 2010 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger Copyright 2010 Texas Instruments Incorpora...

Page 18: ...Layout www ti com Figure 9 Bottom Silkscreen 18 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger SLUU396A January 2010 Revised July 2010 Copyright 2010 Texas Instruments Incorpor...

Page 19: ...tics 6 Schematics Figure 10 bq2461x bq2463x EVM Schematic 19 SLUU396A January 2010 Revised July 2010 bq2461x bq2463x EVM HPA422 Multi Cell Synchronous Switch Mode Charger Copyright 2010 Texas Instrume...

Page 20: ...oduct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engine...

Page 21: ...h statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury...

Reviews: