Setting Programmable bq2060A Options
5-6
data or calibration for the changes to take effect. To reset the bq2060A click
| Options | Initialize Device |.
EEPROM data cannot be accessed on a sealed bq2060A (Pack Configuration
bit 6 is set). To unseal the pack, connect the EEPROM connector, and click |
Options | Unlock Device |. Be sure to remove power from the device and
re−apply to finish the unsealing procedure. To reseal the part, click | Options
| Seal | bq2060A |. Then reset the bq2060A by clicking | Options | Initialize
Device |.
IMPORTANT:
The correct setting of these options is essential to get the best performance.
The settings can be configured using the EEPROM Data Screen.
Figure 5−4. LION EEPROM Data Screen