AMC7834EVM Software Overview
15
SLAU608B – December 2014 – Revised May 2016
Copyright © 2014–2016, Texas Instruments Incorporated
AMC7834 Evaluation Module
Figure 12. ADC Page
To completely activate the ADC block, the
Powerdown Mode
option must be set for reference
configuration. The
Powerdown Mode
option changes the
POWER-MODE
bits of the
Device Configuration
Register
, 0x02. The
Powerdown Mode
allows the user to configure the ADC block to use the internal
reference of the device or an external reference. The reference selection should adhere to the
Reference
Configuration Options
, listed in
. The EVM is currently configured to use the o2.5-V
reference.
displays the options for internal or external reference operation. These options can
be selected in the Powerdown Mode drop-down menu illustrated in
. For default EVM operation,
select Power Mode “11” to use the o2.5-V supply.
Table 14. ADC Block Reference Selection
Power Mode
ADC Ref Buffer Description
0X
OFF
ADC block powered off
10
ON
Configured for internal reference
11
OFF
Configured for external reference
Figure 13. Powerdown Mode Reference Selection
Once the POWER-MODE is configured, individual channels can be enabled by selecting their respective
ADC MUX
button, as shown in
. Selecting a channel enables the button’s respective indicator
field for register readout. To view the contents of the read in volts, select
Display ADC Value in Volts
.