ADS9120EVM-PDK Operation
17
SBAU262 – August 2016
Copyright © 2016, Texas Instruments Incorporated
ADS9120EVM-PDK
6.2
Register Map Configuration Tool
The register map configuration tool allows the user to view and modify the registers of the ADS9120. This
tool can be selected by clicking on the Register Map Config radio button at the Pages section of the left
pane, as indicated in
. On power-up, the values on this page correspond to the Host
Configuration Settings that enable ADC sampling at the maximum sampling rate specified for the ADC.
The register values can be edited by double-clicking the corresponding value field. If interface mode
settings are affected by the change in register values, this change reflects on the left pane immediately.
The effect of changes in the register value reflect on the ADS9120 device on ADS9120EVM-PDK based
on the Update Mode selection, as described in
Figure 11. Register Map Configuration
through
describe the data collection and analysis features of the ADS9120EVM-
PDK GUI.