![Texas Instruments ADS79 EVM-PDK Series Manual Download Page 39](http://html1.mh-extra.com/html/texas-instruments/ads79-evm-pdk-series/ads79-evm-pdk-series_manual_1095337039.webp)
CS
Sample
CHy
SCLK
Sample
CH0
Sample
CH1
Data CHx
Data CHy
Data CH0
SDO
t
CYCLE
AUTO-2 Start
SDI
Scan channels CH0 ,CH1 and CH2
Data CH1
Sample
CH2
Data CH2
AUTO-2
AUTO-2
AUTO2
AUTO-2
Frame N
Frame (N + 1)
Frame (N + 2)
Frame (N + 3)
39
ADS7950, ADS7951, ADS7952, ADS7953, ADS7954, ADS7955
ADS7956, ADS7957, ADS7958, ADS7959, ADS7960, ADS7961
SLAS605C – JUNE 2008 – REVISED JULY 2018
Product Folder Links:
ADS7950 ADS7951 ADS7952 ADS7953 ADS7954 ADS7955 ADS7956 ADS7957 ADS7958
Copyright © 2008–2018, Texas Instruments Incorporated
shows an example in which Auto-2 mode is used to scan channels 0, 1, and 2. Auto-2 mode is
selected to scan all channels until channel 2 (CH2) in ascending order by programming the Auto-2 register as
described in
. The device enters Auto-2 mode on receiving the Auto-2 mode command in the Nth
frame. This step causes the MUX to switch to CH0 in the (N+1)th frame. In the (N+2)th frame, the ADC samples
and shifts out the conversion results for CH0 because the MUX internally switches to CH1. In the (N+3)th frame,
the ADC samples and the shifts out the conversion result for CH1 and the MUX also switches to CH2, and so on.
When this process reaches the maximum selected channel, CH2 in this case, the device returns to CH0 and
repeats the cycle as long as the device remains in Auto-2 mode. Entering Auto-2 mode from any other mode
also causes the device to restart from CH0. Additionally, modifying the contents of the for Auto-2 program
register while operating in Auto-2 also causes the device to scan for restart from CH0.
Figure 56. Example Auto-2 Mode Timing Diagram