![Texas Instruments ADS79 EVM-PDK Series Manual Download Page 2](http://html1.mh-extra.com/html/texas-instruments/ads79-evm-pdk-series/ads79-evm-pdk-series_manual_1095337002.webp)
2
ADS7950, ADS7951, ADS7952, ADS7953, ADS7954, ADS7955
ADS7956, ADS7957, ADS7958, ADS7959, ADS7960, ADS7961
SLAS605C – JUNE 2008 – REVISED JULY 2018
Product Folder Links:
ADS7950 ADS7951 ADS7952 ADS7953 ADS7954 ADS7955 ADS7956 ADS7957 ADS7958
Copyright © 2008–2018, Texas Instruments Incorporated
Table of Contents
1
Features
..................................................................
2
Applications
...........................................................
3
Description
.............................................................
4
Revision History
.....................................................
5
Device Comparison Table
.....................................
6
Pin Configuration and Functions
.........................
7
Specifications
.......................................................
7.1
Absolute Maximum Ratings ....................................
7.2
ESD Ratings............................................................
7.3
Recommended Operating Conditions .....................
7.4
Thermal Information: TSSOP..................................
7.5
Thermal Information: VQFN ....................................
7.6
Electrical Characteristics: ADS7950, ADS7951,
ADS7952, ADS7953 ................................................
7.7
Electrical Characteristics, ADS7954, ADS7955,
ADS7956, ADS7957 ................................................
7.8
Electrical Characteristics, ADS7958, ADS7959,
ADS7960, ADS7961 ................................................
7.9
Timing Requirements ..............................................
7.10
Typical Characteristics (All ADS79xx Family
Devices) ...................................................................
7.11
Typical Characteristics (12-Bit Devices Only).......
7.12
Typical Characteristics (12-Bit Devices Only).......
8
Detailed Description
............................................
8.1
Overview .................................................................
8.2
Functional Block Diagram .......................................
8.3
Feature Description.................................................
8.4
Device Functional Modes........................................
8.5
Programming...........................................................
9
Application and Implementation
........................
9.1
Application Information............................................
9.2
Typical Applications ................................................
10
Power Supply Recommendations
.....................
11
Layout
...................................................................
11.1
Layout Guidelines .................................................
11.2
Layout Examples...................................................
12
Device and Documentation Support
.................
12.1
Documentation Support ........................................
12.2
Related Links ........................................................
12.3
Receiving Notification of Documentation Updates
12.4
Community Resources..........................................
12.5
Trademarks ...........................................................
12.6
Electrostatic Discharge Caution ............................
12.7
Glossary ................................................................
13
Mechanical, Packaging, and Orderable
Information
...........................................................
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision B (July 2015) to Revision C
Page
•
Changed
0 to 2.5 V and 0 to 5 V
to
0 to V
REF
and 0 to 2 x V
REF
in
Input Range
Features bullet .........................................
•
Changed GPIO
Features
bullet .............................................................................................................................................
•
Changed
Optical Line Card Monitoring
and
Multi-Channel, General-Purpose Signal Monitoring
Applications bullets..........
•
Changed
(0 V to 2.5 V and 0 V to 5 V)
to
(0 V to V
REF
and 0 V to 2 × V
REF
)
in
Description
section .....................................
•
Deleted
Companion Products
table........................................................................................................................................
•
Changed RGE to RHB for two 32-pin VQFN pin diagrams ...................................................................................................
•
Added 30-pin DBT package ..................................................................................................................................................
•
Changed I/O column of
Pin Functions: TSSOP Packages
table to show full definition instead of abbreviation ...................
•
Added
active low
to definition of CS pin in
Pin Functions: TSSOP Packages
table ..............................................................
•
Changed pin name and description of Alarm pin in
Pin Functions: TSSOP Packages
table ...............................................
•
Added settings to description of Range pin in
Pin Functions: TSSOP Packages
table: added (1) to high and (0) to low ....
•
Added
active low
to description of CS pin in
Pin Functions: VQFN Packages
table .............................................................
•
Changed pin name and description of Alarm pin in
Pin Functions: VQFN Packages
table ..................................................
•
Changed value of
Input current to any pin except supply pins
row from ±10 mA (max) to –10 mA (min) and 10 mA
(max) in
Absolute Maximum Ratings
table ...........................................................................................................................
•
Changed
VBD = 1.7 V to 5.25 V
to
VBD = 1.7 V to +VA
in condition statement.................................................................
•
Changed minimum specification from –1 LSB to –0.99 LSB in first row of
Differential linearity
parameter.........................
•
Added
input
to
Reference input resistance
parameter name ...............................................................................................
•
Changed maximum specification from
FFC Hex
to
4092 LSB
in
Alarm Setting
parameters ..............................................
•
Changed unit from
Numbers
to
Conversion
in
Invalid conversions after power up or reset
parameter .............................
•
Changed
VBD = 1.7 V to 5.25 V
to
VBD = 1.7 V to +VA
in condition statement ................................................................