4.1  Technical Features

Model:

TMD MK3 SOS

Manufacturer:

TEXA S.p.A.

CPU:

ARM Cortex M0 with LIN BUS type
interface

Visible warnings:

Adjustable intensity red LED

Audible warnings:

Built-in electronic buzzer

Power supply:

12 Vdc

Length of connection cable:

2.5 m

Consumptions:

0.75 mAdc in standby mode (no LED)

Maximum consumption 20 mAdc

Storage and operation humidity:

10% ÷ 80 % without condensation.

Operating temperature:

- 30 ÷ 70 °C

Storage temperature:

- 40 ÷ 85 °C

Safety:

EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 + AC:2011 +
A2:2013

Electromagnetic compatibility:

EN 55022

EN 55024

ISO 7637-1

ISO 7637-2

Regulations / Directives:

UN ECE R10

R&TTE 1999/05/EC (complete system
analysis)

ROHS 2011/65 EU

Dimensions:

Weight:

12 g

11

en

Summary of Contents for TMD I/O EXPANDER

Page 1: ...ENGLISH 5 en...

Page 2: ...2...

Page 3: ...ACY 15 5 1 Technical Features 16 5 2 Regulatory Information 17 5 3 Installation 18 5 4 Use 19 6 TMD MK3 ACTUATOR LOCK 20 6 1 Technical Features 21 6 2 Regulatory Information 23 6 3 Installation 24 7 T...

Page 4: ...Regulatory Information 48 10 3 Description 49 10 4 Installation 50 10 5 Use 51 11 TMD MK3 PRIVACY BTLE 52 11 1 Technical Features 53 11 2 Regulatory Information 54 11 3 Inserting the Battery 55 11 4...

Page 5: ...INSTALLATION MANUAL OF THE TMD MK3 EDR ACCESSORIES REVIEW OF THE MANUAL This document is revision 08 of the TMD MK3 EDR accessories technical manual Issue date 30 03 2018 5 en...

Page 6: ...keting requirement the company may do so at any time without prior notice This manual is to be considered an essential part of the product it refers to If it is resold the original buyer is therefore...

Page 7: ...only select and prompt compatible TEXA devices This does not exclude the presence of other sources of communication or disturbance THE EFFICIENCY AND QUALITY OF BLUETOOTH WiFi AND HSUPA COMMUNICATION...

Page 8: ...2 SAFETY RULES Follow the indications in the TMD MK3 EDR installation manual regarding safety 8...

Page 9: ...3 ACCESSORIES FOR TMD MK3 EDR This manual illustrates the installation of the accessories available for TMD MK3 EDR 9 en...

Page 10: ...n assistance request to the Operations Centre The device can be used in case of an emergency a panic attack a sudden illness of the driver TMD MK3 SOS is equipped with a built in red LED a warning buz...

Page 11: ...5 m Consumptions 0 75 mAdc in standby mode no LED Maximum consumption 20 mAdc Storage and operation humidity 10 80 without condensation Operating temperature 30 70 C Storage temperature 40 85 C Safety...

Page 12: ...OS device complies with the essential requirements and with all further provisions defined by the R TTE 1999 5 EC complete system analysis and RoHS 2011 65 EU directives A complete copy of the Declara...

Page 13: ...t also easy to reach in case of an emergency 1 TMD MK3 EDR 2 Y shaped cable 3 TMD MK3 SOS Proceed as follows 1 Secure TMD MK3 SOS in the most appropriate position 2 Connect the TMD MK3 SOS cable to th...

Page 14: ...ollows 1 Press the SOS button for approximately 2 seconds 2 Release the button 3 Make sure the backlighting of the button turned on weak backlighting 4 Press the SOS button for more than two seconds I...

Page 15: ...n is a device through which you can disable the geolocation using TMD MK3 EDR TMD MK3 PRIVACY is equipped with built in green LED a warning buzzer a connection cable Do not use aggressive cleansers es...

Page 16: ...le 2 5 m Consumptions 0 75 mAdc in standby mode no LED Maximum consumption 20 mAdc Storage and operation humidity 10 80 without condensation Operating temperature 30 70 C Storage temperature 40 85 C S...

Page 17: ...CY device complies with the essential requirements and with all further provisions defined by the R TTE 1999 5 EC complete system analysis and RoHS 2011 65 EU directives A complete copy of the Declara...

Page 18: ...o easy to reach in case of an emergency 1 TMD MK3 EDR 2 Y shaped cable 3 TMD MK3 PRIVACY Proceed as follows 1 Secure TMD MK3 PRIVACY in the most appropriate position 2 Connect the TMD MK3 PRIVACY cabl...

Page 19: ...te the geolocation When pressing the button you will see visible warnings through the LED and hear audible warnings through the built in electronic buzzer The device s functionality and the way it is...

Page 20: ...ough a badge or smartphone If the recognition is successful the device allows vehicle ignition Otherwise the engine cannot be started SHORT STOPS Short stop means that the vehicle is restarted within...

Page 21: ...c Consumptions 20 mAdc Storage and operation humidity 10 80 without condensation Operating temperature 30 70 C TEXA S p A proprietary device Storage temperature 40 85 C Safety EN 60950 1 2006 A11 2009...

Page 22: ...The output protection inhibitory control is transferred to the fuses installed in the vehicle s electrical circuit 22...

Page 23: ...LOCK device complies with the essential requirements and with all further provisions defined by the R TTE 1999 5 EC complete system analysis and RoHS 2011 65 EU directives A complete copy of the Decl...

Page 24: ...relay has a maximum range of 10 A 1 TMD MK3 EDR 2 Y shaped cable 3 TMD MK3 ACTUATOR LOCK Proceed as follows 1 Secure TMD MK3 ACTUATOR LOCK in the most appropriate position 2 Connect the two TMD MK3 AC...

Page 25: ...o send a request for assistance to the Operations Centre The device can be used in case of an emergency a panic attack a sudden illness of the driver TMD MK3 SOS is equipped with a built in red LED a...

Page 26: ...on Operating temperature 30 50 C Storage temperature 40 85 C Internal battery Model 3 7 V Lithium Ion 602248 PCM Capacity 600 mAh Internal battery charging management Charging temperature 0 30 C The b...

Page 27: ...Dimensions Weight 90 g with cable 27 en...

Page 28: ...REE SOS device complies with the essential requirements and with all further provisions defined by the R TTE 1999 5 EC complete system analysis and RoHS 2011 65 EU directives A complete copy of the De...

Page 29: ...7 3 Description 1 Connector 2 RGB LED 3 Button A I 4 Button A II 5 Call button 6 SOS button 7 Speaker Microphone 29 en...

Page 30: ...re with driving but also easy to reach in case of an emergency 1 TMD MK3 EDR 2 Y shaped cable 3 TMD MK3 HANDS FREE SOS Proceed as follows 1 Secure TMD MK3 HANDS FREE SOS in the most appropriate positi...

Page 31: ...an extended amount of time allows the transmission of a request for assistance to the Operations Centre pressing the CALL button allows you to hang up ending the conversation with the Operations Cent...

Page 32: ...ge the device allows you to identify who is driving the vehicle in which the device is installed TMD MK3 MULTIREADER is equipped with 3 integrated LEDs a reader for NFC technology a track reader for M...

Page 33: ...12 Vdc Length of connection cable 2 5 m Consumptions 2 mAdc in standby 200 mAdc maximum Storage and operation humidity 10 80 without condensation Operating temperature 30 50 C Storage temperature 40...

Page 34: ...Dimensions Weight 170 g 34...

Page 35: ...ADER device complies with the essential requirements and with all further provisions defined by the R TTE 1999 5 EC complete system analysis and RoHS 2011 65 EU directives A complete copy of the Decla...

Page 36: ...escription 1 Reader for NFC technology 2 Track reader for Magnetic Stripe technology 3 LED unit Blue LED Green LED Red LED 4 Video camera for Barcode technology reading and proximity sensor 5 Connecto...

Page 37: ...rfere with driving but also easy to reach in case of an emergency 1 TMD MK3 EDR 2 Y shaped cable 3 TMD MK3 MULTIREADER Proceed as follows 1 Secure TMD MK3 MULTIREADER in the most appropriate position...

Page 38: ...with allow you to recognise the badge by putting it close to the presence sensor by swiping its magnetic stripe through the specific slot by putting it close to the optical sensor on its barcode side...

Page 39: ...u to verify the presence of the keys inside the vehicle once it is returned TMD MK3 KEYLESS is made up of two parts support key fob with built in Bluetooth module TMD MK3 KEYLESS is equipped with red...

Page 40: ...ell Consumptions 26 A in standby Storage and operating humidity 10 80 without condensation Operating temperature 20 58 C Storage temperature with battery cell disconnected 30 70 C Directives RED 2014...

Page 41: ...cturer TEXA S p A declares that the type of radio equipment TMD MK3 KEYLESS is compliant with the RED 2014 53 EU and RoHS 2011 65 EU directives The complete text of the EU declaration of conformity is...

Page 42: ...te the key fob s top casing from the bottom one 3 Flip over the top casing and insert the battery into its slot with the positive pole facing upwards 4 Reposition the top casing onto the bottom one AT...

Page 43: ...be customised based on specific needs If the TMD MK3 KEYLESS must be fastened inside the passenger compartment it must be positioned where it does not compromise safe driving or the proper operation...

Page 44: ...communicates via Bluetooth to the TMD MK3 EDR that the keys have been positioned inside the vehicle correctly At this point based on the accessories installed and on the customisation of their firmwa...

Page 45: ...activate the door unlock function The device has a particular book shape thanks to which after installing it on the windscreen you can adjust the inclination of the front part so to optimise the view...

Page 46: ...le 2 5 m Consumptions 100 mAdc Storage and operation humidity 10 80 without condensation Operating temperature 20 65 C Storage temperature 40 85 C Regulations Directives UN ECE R10 RED 2014 53 EU comp...

Page 47: ...Weight 250 g 47 en...

Page 48: ...S p A declares that the type of radio equipment TMD MK3 TEXA SHARE is compliant with the RED 2014 53 EU complete system analysis and RoHS 2011 65 EU directives The complete text of the EU declaration...

Page 49: ...ED back side of the device Green available Yellow not available RED busy Blue maintenance 2 NFC technology reader back side of the device 3 Connector 4 Function buttons A I A II A III 5 SOS button 6 L...

Page 50: ...ed as follows 1 Secure TMD MK3 TEXA SHARE in the most appropriate position 2 Connect the TMD MK3 TEXA SHARE cable to the Y shaped cable 3 Insert the connector of the Y shaped cable into the L1 input o...

Page 51: ...it has already been reserved Red the vehicle cannot be reserved for example due to a fault Blue the vehicle is being maintenanced 3 If the vehicle is available the doors are unlocked and you may acces...

Page 52: ...BTLE button is a device through which you can disable the geolocation using TMD MK3 EDR TMD MK3 PRIVACY BTLE is equipped with a built in green red LED a warning buzzer Do not use aggressive cleansers...

Page 53: ...450 cell Consumptions 26 A in standby Storage and operation humidity 10 80 without condensation Operating temperature 20 58 C Storage temperature with battery cell disconnected 30 70 C Directives RED...

Page 54: ...TEXA S p A declares that the type of radio equipment TMD MK3 PRIVACY BTLE is compliant with the RED 2014 53 EU and RoHS 2011 65 EU directives The complete text of the EU declaration of conformity is a...

Page 55: ...he button facing upwards 2 Unlock the upper case by delicately turning it counter clockwise 3 Lift the upper case 4 Flip over the upper case and insert the battery into its slot with the positive pole...

Page 56: ...ATTENTION Risk of explosion if the battery is replaced with another one of the wrong type Dispose of the batteries following the instructions 56...

Page 57: ...atic or follow a procedure that can be customised based on specific needs If the TMD MK3 PRIVACY BTLE must be fastened inside the passenger compartment using specific supports it is provided with it m...

Page 58: ...vate the geolocation When pressing the button you will see visible warnings through the LED and hear audible warnings through the built in electronic buzzer The device s functionality and the way it i...

Page 59: ...aring market and it is can be easily recognised among the other TMD devices thanks to its orange label The connection to TMD MK3 takes place via LIN BUS TBus Through TMD I O EXPANDER it is possible fo...

Page 60: ...e 3908243 2 P2 connector not used and not connected to the rest of the device 3 P3 4 way connector to connect the actuator lock control code 3908244 4 P4 4 way connector for the TMD MK3 EDR connection...

Page 61: ...y power transmitted 3 dBm Power supply 12 Vdc through LIN wiring Consumptions Normal max 280 mAdc at 12 Vdc Standby 3 mAdc at 12 Vdc Storage and operation humidity 10 80 without condensation Operating...

Page 62: ...protection inhibitory control is transferred to the fuses installed in the vehicle s electrical circuit Dimensions mm TMD I O EXPANDER TMD BLINKER Weight TMD I O EXPANDER 92 g TMD BLINKER 52 g includi...

Page 63: ...The manufacturer TEXA S p A declares that the type of radio equipment TMD I O EXPANDER is compliant with the RED 2014 53 EU directive The complete text of the EU declaration of conformity is availabl...

Page 64: ...and away from heat sources The TMD I O EXPANDER must be easy to reach in case of an emergency deactivation The system relay has a maximum range of 10 A 1 TMD MK3 EDR 2 Y shaped cable code 3904674 3 T...

Page 65: ...Insert the connector of the TMD I O EXPANDER code 3908285 into the connector of the Y shaped cable code 3904674 4 Insert the connector of the TMD I O EXPANDER code 3908285 into the P4 input of TMD I O...

Page 66: ...13 ENVIRONMENTAL INFORMATION For information regarding the disposal of this product please see the pamphlet supplied 66...

Page 67: ...ject to the direction and coordination activities of Opera Holding S r l Paid up share capital 1 000 000 R E A Economic Administrative Index No 208102 Legal Representative Bruno Vianello Phone 39 0422...

Reviews: