TVME200 User Manual Issue 1.1.0
Page 7 of 26
2 Technical Specification
VMEbus Slave Interface
According to VMEbus specification, ANSI / VITA 1-1994, 6U Board
Short I/O
VME A16, D08/16,
Address Modifier: 29, 2D
Size: 1 Kbytes (256 Bytes / IP)
Standard Memory
VME A24, D08/16,
Address Modifier: 39, 3A, 3D, 3E
Size: programmable from 32 Kbytes to 2 Mbytes per IP
Extended Memory
VME A32, D08/16,
Address Modifier: 09, 0A, 0D, 0E
Size: fixed, 8 Mbytes per IP
Interrupts
VME IRQ1-7
IP Interface
According to IndustryPack specification ANSI / VITA 4-1995
IP Slots
Four single size or two double size with front panel I/O
Mapping of IP Interrupts to
VMEbus
Programmable by software or selection of predefined sets by a
rotary switch
I/O access
50 pin 0.1 inch flat ribbon cable connector per IP, mounted in the
front panel
Additional Rear I/O (TVME200-20 only)
DMA
32 MHz
Not supported
Not supported
Status LEDs
ACK LED for each IP slot
+5V Power LED for each IP slot
+12V and –12V Power LED
Protection
Self healing fuses and RF-filtering on all IP power lines
Operating Data
300 mA typical @+ 5 VDC
1 mA typical @+ 12 VDC
1 mA typical @ -12 VDC
Power Requirements
without IP Modules
Additional Power is required by IP modules
Temperature Range
Operating
Storage
– 40°C to + 85C
– 40°C to + 125°C
MTBF
366000 h
Weight
260 g – no IndustryPack inserted
Size
Singe Size 6U Euro Card
Humidity
5 – 95 % non-condensing
Figure 2-1 : Technical Specification
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com