TVME200 User Manual Issue 1.1.0
Page 18 of 26
IP C Control Register
VME A16 Base A 0x02C3
Bit
Symbol
Description
Access
Reset Value
7
IP C, Reset 1 = reset is initiated
Remains ‘1’, until the IP reset has been completed
and is then set to ‘0’ by the on board logic. It can
be read to verify the status of the reset.
R/W 0
6 reserved
R
undefined
5 reserved
R
undefined
4 reserved
R
undefined
3 reserved
Carry random information
R undefined
2
IP C, Error
1 = error signal is active
R
0
1
IP C, INT1
R
0
0
IP C, INT0
Interrupt status
1 = indicates a pending interrupt request
R 0
IP D Control Register
VME A16 Base A 0x03C3
Bit
Symbol
Description
Access
Reset Value
7
IP D, Reset 1 = reset is initiated
Remains ‘1’, until the IP reset has been completed
and is then set to ‘0’ by the on board logic. It can
be read to verify the status of the reset.
R/W 0
6 reserved
R
undefined
5 reserved
R
undefined
4 reserved
R
undefined
3 reserved
Carry random information
R undefined
2
IP D, Error
1 = error signal is active
R
0
1
IP D, INT1
R
0
0
IP D, INT0
Interrupt status
1 = indicates a pending interrupt request
R 0
Figure 4-4 : IP Control Registers (IP C / IP D)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com