![Tews Technologies TPMC810 User Manual Download Page 17](http://html1.mh-extra.com/html/tews-technologies/tpmc810/tpmc810_user-manual_1093653017.webp)
TPMC810 User Manual Issue 2.0.0
Page 17 of 22
Address
Name
Composition and Remarks
0x10
Frame
Information
1 bit indicating, if the message contains a Standard or Extended frame
1 Remote Transmission Request bit
4 bits for the Data Length Code, indicating the amount of data bytes
0x11, 0x12
Identifier Byte
1, 2
Standard Frame: 11 Identifier bits
Extended Frame: 16 Identifier bits
0x13, 0x14
Identifier Byte
3, 4
Extended Frame only: 13 Identifier bits
Frame type
Standard: 0x13 – 0x1A
Extended: 0x15 – 0x1C
Data Byte
1 - 8
Up to 8 data bytes as indicated by the Data Length Code
Table 5-4 : Rx- and Tx-buffer in PeliCAN Mode
The whole Receive FIFO (64 bytes) can be accessed using CAN addresses 32 to 95.
A read access of the Tx-buffer can be done using CAN addresses 96 to 108.
For more information about the registers with respect to read and/or write access, bit definition and reset