background image

4 Zone DMX and RF wall panel

for Tunable White LED strip

www.teucerled.co.uk

V002-11-2019

Synchronising the wall panel to the receiver

4) 

To restore the receiver to the factory default settings 

and delete the allocated controller, press and hold the 

match button on the receiver longer than 5 seconds 

until the LED indicator flashes quickly 5 times.

Match button

LED Indicator

R3C

POWER

ZONE

ZONE

ZONE

ZONE

S

SCENE

BRIGHT

BRIGHT

Press the zone

you wish to allocate

3) 

Repeat the process to allocate zones for all 

receivers.

Note! RF technology allows for greater flexibility when it comes to controlling simple or complex lighting installations 

without the need of additional cabling. 

There are some limitations where installations have the receivers enclosed in electrical boxes or hidden away in a ceiling 

, reducing the RF signal strength and therefore the communication range. 

 

In order to overcome these RF Signal restrictions we suggest the following when synchronising our RF controllers and 

receivers:

• 

Keep the distance within 10 meters from the controller to the receiver. The remote can operate up to 30 meters if 

signal is uninterrupted by obstacles.

• 

When expanding your lighting, always try and use a signal repeater (PR-RGB(N)), where possible.

1)

 Ensure the receiver has power. Press the match button on the receiver. LED Indicator will start flashing 

slowly.

2) 

Choose the zone you wish to allocate on the panel within 5 seconds after pressing the match button.

The LED indicator on the receiver will flash rapidly 5 times and then stop flashing. The controller is now 

synchronised with the receiver.

Note! DMX is a standard protocol for digital communication which allows control of DMX devices / lighting from a 

compatible DMX controller.

We recommend using the controller when controlling all lighting as a single zone.

Please note that with the DIMDMX1CH(N) one can use the manual button to switch ON the connected LED strips and 

check the operation by cycling through the various modes.

 

• 

When expanding your lighting always try and use a signal repeater (PR-RGB) where possible.  

• 

If using DMX over 55mtrs it is recommended to use a DMX amplifier for longer distances.

• 

If the recoil effect occurs because of the long DMX signal line or bad DMX line quality, please try to connect a 0.25W 

90-120Ω terminal resistor at the end of the DMX signal line.

Synchronising the wall panel to the DMX decoder

Address Setting in Tunable White mode when using a single decoder: 

Zone

WW DMX Address

CW DMX Address

Tunable White Zone 1

001

002

Tunable White Zone 2

003

004

Tunable White Zone 3

005

006

Tunable White Zone 4

007

008