Synchronising the remote to receiver
Brighter for longer
CONTROLLER AND RECEIVER
www.teucerled.co.uk
1)
Ensure the receiver has power. Press the match button on the receiver. Indicator will start flashing.
3) To restore to factory default settings and delete the allocated con-
troller, press and hold the match button longer than 5 seconds.
2)
Press any button on the remote to allocate the receiver within 5 seconds after pressing the match button.
The indicator will stop flashing, and the controller will be synchronised.
Match bu�on
R4C
Press any bu�on to
allocate
the receiver
Troubleshoot
Problem
Cause
Corrective
No light
• No power.
• Wrong connection or unsecure connec-
tion.
• Check the power.
• Check the connection.
Wrong Colour
• Wrong connection of RGBW wires.
• Re trace and reconnect
RGBW wires.
Uneven intensity be-
tween front and rear of
the strip, with voltage
drop
• Output cable is too long.
• Cable diameter is too small.
• Overload beyond driver capability.
• Overload beyond receiver capability.
• Reduce cable or loop supply.
• Change to a thicker cable.
• Replace with a suitable high-
er power driver.
• Add a power repeater.
No response
from the remote
• The battery has no power.
• Beyond controllable distance.
• The controller isn’t synchronised with the
remote.
• Replace battery.
• Reduce remote to receiver
distance.
• Re-sync the remote.
LR-RGB/RGBW and R4C